Conditions
Do not operate the UPS in an environment where the ambient temperature is outside the limits given in the
Specifications section of this manual.
Connection to the Utility Power
Plug the UPS into an electrical outlet. Do not plug it into an outlet that already uses a heavy electric load
(e.g., an air conditioner, refrigerator or laser printer).
120 V AC Version
The 120 V AC version of the MANHATTAN Line Interactive UPS is furnished with a line cord terminated
with a standard NEMA 5-15P three-pronged plug. The UPS must be plugged into a two-pole, three-wire
grounding receptacle. If an extension cord must be used, use a three-wire grounding type rated at least
8 Amps. Plug the UPS into a two-pole, three-wire grounded receptacle only. Avoid using extension cords
and adapter plugs.
220 V AC Version
The 220 V AC version is furnished with one output power cord for connection to computer equipment
having IEC 320 male appliance couplers at their input. In most cases this will not be a problem, as the
input cord that currently powers your computer equipment may be swapped with the supplied output
cord. Hence, the swapped output line cord can be used instead as the input line cord for the UPS.