2-44
DESCRIPTION AND USE OF THE OPTIONS
1 - PREHEATING ELEMENT
Enables the engine to be kept warm during prolonged periods of stoppage and thus improves
engine star ting.
SUPPLY CHARACTERISTICS OF PREHEATING SYSTEM:
• Rated range of power: 220-240V ; 50-60Hz
• Current consumed: 4,5A
• Equipment in class 1
• Equipment connectable only on feeder circuit TT or TN
• Categor y of insulation 2
ENVIRONMENTAL CONDITIONS FOR USE:
• Maximum ambient temperature for using preheating: +25 °C
• Pollution level 2
CONDITIONS FOR CONNECTION AND USE OF PREHEATING:
- The preheating system should not be used for an external ambient temperature higher than + 25° C.
- It is essential that the power supply to the preheating system is:
• Effected with a cable that conforms to the installation standards in force and contains a protective ear th conductor.
• Contains an appropriate sectioning system.
• Incorporate an appropriate safety system against shor t circuits (fuses or circuit breaker) and a differential circuit breaker
with 30 mA sensitivity.
- Only connect to and disconnect from the power supply while the unit is off and the I.C. engine is stopped.
2 - EXTERIOR DRAIN-BACK
Enables connection of an attachment for which
drain-back is required.
3 - ELECTROVALVE ON JIB HEAD
Enables use of two hydraulic functions on the attachment circuit.
To make connection of the rapid connectors easier, decompress the hydraulic circuit by pressing button
1 on the electrovalve.
OPERATION
- With button 2 not engaged, button 3 controls a hydraulic function.
- Hold button 2 down, button 3 controls another hydraulic function.
2
3
MT 1436 R PRIVILEGE
MT 1840 R PRIVILEGE
1
Summary of Contents for MT 1058 R PRIVILEGE
Page 1: ......
Page 3: ......
Page 4: ...1 1 1 OPERATING AND SAFETY INSTRUCTIONS...
Page 5: ...1 2...
Page 31: ...1 28...
Page 32: ...2 1 2 DESCRIPTION...
Page 33: ...2 2...
Page 44: ...2 13...
Page 74: ...2 43...
Page 78: ...3 1 3 MAINTENANCE...
Page 79: ...3 2...
Page 84: ...3 7...
Page 92: ...3 15...
Page 104: ...3 27...
Page 116: ...4 1 4 OPTIONAL ATTACHMENTS FOR USE WITH THE RANGE...
Page 117: ...4 2...
Page 119: ...4 4...
Page 129: ...4 14...
Page 130: ...5 1 5 SPECIFIC CANADA...
Page 131: ...5 2...
Page 132: ...5 3 TABLE OF CONTENTS DIMENSIONS AND LOAD CHART MT 1058 R PRIVILEGE 5 4...
Page 135: ...5 6...
Page 136: ...6 1 6 SPECIFIC AUSTRALIA See also the operator s manual supplement 647065 AU...
Page 137: ...6 2...
Page 139: ...6 4...