INSTRUCTIONS FOR REPLACING COMPRESSOR 

IN COMPRESSOR ASSEMBLY 7620443 

230V/60 HZ/3 PHASE 

 

A-2200, A-1100, B-1100, C-1100 SERIES MACHINES 
WITH BRISTOL REPLACEMENT COMPRESSOR 
 

The Bristol model M13A163**** compressor is set up as a 
direct field replacement for the Tecumseh AH7514A 
compressor.  The mounting foot pattern on the Bristol is 
exactly the same as the Tecumseh.  To get the tubing to line 
up, the Bristol compressor should be turned 90

°

.  In the case 

of the 1100 series, the compressor terminal box will be back 
against the ice machine’s bulkhead. 
 
The A, B, and C vintage machines have 3/4” suction lines; the 
Bristol is set up with 5/8”.  A short piece of 5/8” tubing is 
needed to be used as an adapter sleeve.  It will fit the 
compressor suction spud and can be slipped inside the 3/4” 
existing tubing.  All the other tubes are readily field adaptable. 
 
The Bristol does use a different start capacitor, run capacitor, 
and start relay.  These are supplied with service compressors.  
They 

must 

be changed at the time of installation. 

 
The Bristol compressor is wired the same as the Tecumseh 
and will take the same nameplate refrigerant charge.  It is 
important to change the drier whenever opening the 
refrigeration system.  Check your Manitowoc Parts Manual 
for correct drier size. 

E-1100 SERIES MACHINES WITH BRISTOL 
REPLACEMENT COMPRESSORS 
 

The Bristol model M13A163**** compressor is set up as a 
direct field replacement for the Tecumseh AH7514A 
compressor.  The mounting foot pattern on the Bristol is 
exactly the same as the Tecumseh.  The Bristol should be 
installed in the machine with the compressor terminal box to 
the front of the machine.  The process tube can be easily bent 
into position. 
 
The Bristol compressor is wired the same as the Tecumseh 
and will take the same nameplate refrigerant charge. 

 
 
 
If this Bristol compressor is replacing a Copeland Compressor, a lead wire conversion kit, 7621883, may be necessary.  This is 
available through your local Manitowoc distributor. 
 
This replacement compressor may be different than the original compressor and/or have slightly different tubing configurations.  The 
suction line, discharge line, and/or suction service line at the compressor may need to be rerouted, when making this change-out. 
 
 
 
 
 
 
                                                                                                                                                                    

 
                                                                                                                                                                                                       8003184 