124
Part Number: 000015431 Rev01 5/19
Change Head Pressure Contol Valve
NO
Feel
Te
mperature of Discharge Line
after 30 Seconds into Harvest Cycle
(refer to Head Pressure V
alve Diagnostics)
Head Pressure V
alve
is not
in 100% Bypass
Head Pressure V
alve is
in 100% Bypass
Refrigerant Charge
is Incorrect
Evacuate System, Recharge
&
Perform Production Check
Refer to Symptom #2
Refrigeration Operational
Analysis
Table
Refrigerant Charge
is Correct
IMPOR
TA
NT
W
eigh charge as you are recovering, if incorrect evacuate & recharge,
if correct then proceed