4-4
4.4
Adjusting the Burner Gas Pressure
DANGER
Frymaster recommends that ONLY qualified service personnel perform this task.
1.
Ensure that the gas valve knob is in the
OFF
position.
2.
Remove the pressure tap plug from the gas valve assembly.
Typical Valve Assembly
Pressure Tap Plug
3.
Insert the fitting for a gas pressure-measuring device into the pressure tap hole
4.
Place the gas valve in the
ON
position.
5.
Place the power switch in the
ON
position. When the burner has lit and burned steadily for at
least one minute, compare the gas pressure reading to the pressure for the corresponding gas in
the appropriate table below.
Burner Gas Pressure
Gas Pressure
Natural
3" WC
.087 kPa
8.718 mbar
Propane
8.25" WC
2.05 kPa
20.55 mbar
Total Restaurant Supply - https://totalsupply1.com - Toll Free 1-800-944-9304 - Local 507-288-9454
2940 Hwy 14 W, Rochester, MN 55901