28
Part Number 000012545 Rev 02 11/16
Maintenance
Section 4
Removal from Service/Winterization
1. Clean and sanitize the ice machine.
2. Move the toggle switch to the OFF position and turn off
the ice machine.
3. Turn off the water supply, disconnect and drain the
incoming ice-making water line at the rear of the ice
machine and drain the water trough.
4. Energize the ice machine, wait one minute for the
water inlet valve to open and blow compressed air in
both the incoming water and the drain openings in the
rear of the ice machine to remove all water.
5. Move the toggle switch to the OFF position and turn off
the ice machine. Disconnect the electric power at the
circuit breaker or the electric service switch.
6. Fill spray bottle with sanitizer/water solution and spray
all interior food zone surfaces. Do not rinse and allow to
air dry.
7. Replace all panels.
WATER-COOLED ICE MACHINES
1. Perform steps 1-6 under “Removal from Service/
Winterization”.
2. Disconnect the incoming water and drain line from the
water-cooled condenser.
3. Energize the ice machine in the freeze cycle. The
increasing refrigerant pressure will open the water
regulating valve.
4. Blow compressed air through the condenser until no
water remains.
5. Replace all panels.