66
Part Number 040005626 5/17
Safety Limit 3
The harvest float switch hasn’t opened for 10
continuous seconds within 4 minutes of the water
inlet valve energizing.
Possible Cause Checklist
Improper installation
•
Refer to “Installation/Visual Inspection Checklist”
on page 55.
Water System
•
Water dump valve
•
Harvest float valve dirty or defective
•
Low water pressure (20 psig min.)
•
Dirty defective water filter (when used)
•
Loss of water from sump area
•
Dirty/defective water inlet valve
Electrical system
•
Water inlet valve coil defective
•
Harvest float valve defective