8
1/12
Clearance Requirements
Model
Air Cooled
Top
8" (20 cm)
Sides
6" (15 cm)
Back
6" (15 cm)
Front
30" (76 cm)
Heat of Rejection
Heat of Rejection
Air Conditioning
BTUh/kW
Peak
2100/0.62
2600/0.76
General Specifi cations
Temperature Control Setting
36°F setpoint 4°F differential
2°C setpoint 2°C differential
controlled by software
Ice Capacity
23 lbs (10 kg)
Shipping Weight
430 lbs (195 kg)
Product Bin Capacity
19.8lbs (9kg) per bin
CO
2
Regulator Setting
40psi (276 kPa)
Water Regulator Setting
30psi (207 kPa)
Location
The location selected for the Blended Ice Machine must
meet the following criteria.
• The air temperature must be at least 40°F (4°C), but
must not exceed 90°F (32°C), climate class 4.
• The location must not be near heat-generating
equipment or in direct sunlight and must be
protected from weather.
• Water temperature min/max = 40°F/110°F
(4°C/43°C).
• Water pressure min/max = 20 psi/40 psi
(138kPa/276kPa)
• Always use the water supply line supplied when
installing this appliance. Never reuse an old supply
line.
• Main supply CO
2
pressure to Blended Ice
Machine regulator min/max = 55 psi/150 psi
(379kPa/1034kPa)
!
Warning
Carbon Dioxide (CO
2
) displaces oxygen. Exposure
to a high concentration of CO
2
gas causes tremors,
which are followed rapidly by loss of consciousness
and suffocation. If a CO
2
gas leak is suspected,
particularly in a small area, immediately ventilate
the area before repairing the leak. CO
2
lines and
pumps must not be installed in an enclosed space.
An enclosed space can be a cooler or small room
or closet. This may include convenience stores with
glass door self serve coolers. If you suspect CO
2
may build up in an area, venting of the B-I-B pumps
and / or CO
2
monitors must be utilized.