4-3
Section 4
Maintenance
SELF-SANITIZING PROCEDURE
Use sanitizer to remove algae or slime. Do not use it
to remove lime scale or other mineral deposits.
Step 1
Set the toggle switch to the OFF position
after ice falls from the evaporator at the end of a
Harvest cycle. Or, set the switch to the OFF position
and allow the ice to melt off the evaporator.
CAUTION
Never use anything to force ice from the
evaporator. Damage may result.
Step 2
To start self-sanitizing, move the toggle
switch to the CLEAN position.
Step 3
Add the proper amount of Manitowoc Ice
Machine Sanitizer to the water trough.
Model
Amount of Sanitizer
P-520/P-530
3 ounces (90 ml)
Step 4
The ice machine will automatically time out a
ten-minute sanitizing cycle, followed by six rinse
cycles, and then stop. This entire cycle lasts
approximately 25 minutes.
Note:
If the bin requires sanitizing, remove all of the
ice and sanitize it with a solution of 1 ounce (30 ml)
of sanitizer with up to 4 gallons (15 L) of water.
Step 5
When the self-sanitizing process stops, move
the toggle switch to the ICE position to start making
ice again.
Step 6
A.
The ice machine may be set to start and finish
a self-sanitizing procedure, and then
automatically start ice making again.
B.
Wait about one minute into the sanitizing
cycle, then move the toggle switch from
CLEAN to ICE position.
C.
When the self-sanitizing cycle is completed,
an ice making sequence will start
automatically.
Summary of Contents for P Series
Page 2: ...Part Number 80 1125 3 ...
Page 4: ......
Page 11: ...1 4 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 24: ...3 3 Section 3 Ice Machine Operation THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 27: ...3 6 Ice Machine Operation Section 3 THIS PAGE INTENTIONALLY LEFT BLANK ...