Installation Instructions
Section 2
2-4
Electrical Service
GENERAL
WARNING
All wiring must conform to local, state and national
codes.
WARNING
Never use an extension cord. If an outlet is not
within reach of the dispenser power cord, have a
proper amperage outlet wired closer to the
dispenser.
Voltage Phase
Cycle
Maximum Fuse/Circuit Breaker
Minimum Circuit Amps
115/1/60 15
amp
230/1/50 15
amp
ELECTRICAL CORD STRAIN RELIEF
To prevent strain at the electrical connection inside
the dispenser, an electrical cord strain relief device
has been installed on the rear panel of the dispenser.
VOLTAGE
The maximum allowable voltage variation is
±
10%
of the rated voltage at dispenser start-up (when the
electrical load is highest).
WARNING
The dispenser must be grounded in accordance with
national and local electrical codes.
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for
each dispenser.
NOTE: A disconnect means must be provided for
field wiring.
ELECTRICAL RATING
The electrical rating is used to help select the wire
size of the electrical supply. The wire size (or gauge)
also depends on location, materials used, length of
run, etc., so it must be determined by a qualified
electrician.