2-3
Section 2
Installation Instructions
Location of Ice Machine
The location selected for the ice machine must meet
the following criteria. If any of these criteria are not
met, select another location.
•
The location must be indoors.
•
The location must be free of airborne and other
contaminants.
•
The air temperature must be at least 35
°
F (1.7
°
C),
but must not exceed 110
°
F (43.4
°
C).
•
The location must not be near heat-generating
equipment or in direct sunlight.
•
The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
•
The location must allow enough clearance for
water, drain and electrical connections in the
rear
of the ice machine.
•
The location must not obstruct airflow through or
around the ice machine (condenser airflow is in
and out the front). Refer to the chart below for
clearance requirements.
Self-Contained
Air-Cooled
Self-Contained
Water-Cooled
Top/Sides
5” (203 mm)*
5” (127 mm)*
Back
5” (127 mm)*
5” (127 mm)*
*
NOTE: The ice machine may be built into a cabinet.
There is no minimum clearance requirement for the
top or left and right sides of the ice machine.
The
listed values are recommended for efficient operation
and servicing only.
CAUTION
The ice machine must be protected if it will be
subjected to temperatures below 32
°
F (0
°
C).
Failure caused by exposure to freezing
temperatures is not covered by the warranty.
See “Removal from Service/Winterization” on page
4-11.
Ice Machine Heat of Rejection
Series Heat
of
Rejection*
Ice Machine Air Conditioning**
Peak
Q130 2100 3300
Q210 2400 3400
Q270 3800 6000
* B.T.U./Hour
** Because the heat of rejection varies during the ice making
cycle, the figure shown is an average.
Ice machines, like other refrigeration equipment,
reject heat through the condenser. It is helpful to
know the amount of heat rejected by the ice machine
when sizing air conditioning equipment where self-
contained air-cooled ice machines are installed.
Summary of Contents for Q210 series
Page 8: ...1 4 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 22: ...3 6 Ice Machine Operation Section 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 33: ...4 11 Section 4 Maintenance THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...4 12 Maintenance Section 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 39: ......