4-5
Section 4
Maintenance
G. Remove the Ice Damper
Q130
•
Grasp left side of ice damper and apply pressure
against the right-hand ice damper mounting
bracket.
•
Pull forward on the ice damper until the left-hand
mounting pin disengages.
Installation
•
Grasp the right side of ice damper and place left
hand pin in the mounting bracket.
•
While applying pressure against the left-hand
mounting bracket push the damper until the right-
hand mounting pin engages.
Q210/Q270
•
Grasp ice damper and apply pressure toward the
left hand mounting bracket.
•
Apply pressure to the right hand mounting
bracket with thumb.
•
Pull ice damper forward when the right hand ice
damper pin disengages.
Installation
•
Place ice damper pin in left hand mounting
bracket and apply pressure toward the left hand
mounting bracket.
•
Apply pressure to the right hand mounting
bracket with thumb.
•
Push ice damper toward evaporator until right
hand damper pin engages.