28
D. Hand descale the removed part(s) in a properly
mixed solution of descaler and water.
Solution Type
Water
Mixed With
Descaling
1 gal. (4 L)
16 oz (500 ml) Cleaner/Descaler
Part Number 000000084
E. Use a soft-bristle brush or sponge (NOT a wire
brush) to carefully clean the parts.
F. Use the solution and a brush or sponge to clean
all disassembled components and the inside of
the bin.
G. Rinse all cleaned parts with clear potable water.
H. Mix a solution of sanitizer and water.
Solution Type
Water
Mixed With
Sanitizer
3 gal. (11 L)
2 oz (60 ml) sanitizer
Part Number 94-0565-3
I. Use the sanitizer/water solution and a sponge to
sanitize all removed components and the inside
of the bin. Do not rinse the sanitized parts.
NOTE: Descale, rinse and spray sanitizer on all interior and
exterior areas of the evaporator discharge spout on UFF
and UNF models.