33
Removal from Service/Winterization
,
Caution
If water is allowed to remain in the ice machine
in freezing temperatures, severe damage to some
components could result. Damage of this nature is not
covered by the warranty.
Follow the procedure below.
1. Disconnect the electric power at the circuit breaker or
the electric service switch.
2. Turn off the water supply.
3. Disconnect and drain the incoming ice-making water
line at the rear of the ice machine.
4. Disconnect drain tubing and drain water into
container and discard.
5. Make sure water is not trapped in any of the water or
drain lines.
6. Water cooled - Use compressed air to remove all
water from the condenser.