75
Bin Thermostat
Closed?
NO
Replace Thermostat
YES
Ice Contacting Thermostat?
Remove Ice - Allow To Warm And Retest
Adjusting Closes
Thermostat?
Verify New Setting Cycles
Machine On/Off
YES
NO
NO
YES
YES
Left Side Chute Switch Closed?
NO
Adjust Or Replace
Actuator
Ice Contacting
Actuator?
Remove Ice And
Retest
Actuator Functions?
Replace Switch
YES
NO
NO
YES
YES
Right Side Chute Switch Closed?
NO
Adjust Or Replace
Actuator
Ice Contacting
Actuator?
Remove Ice And
Retest
Actuator Functions?
Replace Switch
YES
NO
NO
YES
YES