32
CLEANING THE AIR FILTER AND CONDENSER
n
Warning
Disconnect electric power to the ice machine at the
electric service switch before cleaning the condenser.
The condenser fins are sharp. Use care when cleaning
them.
Air-Cooled Condenser
Clean the condenser at least every six months. Follow the
steps below.
1. Some models have a washable filter. Clean the filter
with a mild soap and water solution.
2. Shine a flashlight through the condenser to check
for dirt between the fins. Blow compressed air
through the condenser fins from the inside or use
a commercial condenser coil cleaner. Follow the
directions and cautions supplied with the cleaner.
3. Straighten any bent condenser fins with a fin comb.
4. Carefully wipe off the fan blades and motor with
a soft cloth. Do not bend the fan blades. If the fan
blades are excessively dirty, wash with warm, soapy
water and rinse thoroughly.
n
Warning
If you are cleaning the condenser fan blades with water,
cover the fan motor to prevent water damage.