Refrigeration System
Section 7
7-46
Part Number 80-1480-3
S1800 SERIES
Remote
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
8.9-9.8
10.0-11.0
10.7-11.7
1-2.5
80/26.7
9.0-9.9
10.1-11.1
10.8-11.9
90/32.2
9.2-10.1
10.1-11.1
10.8-11.9
100/37.8
9.6-10.5
10.0-11.0
11.6-12.7
110/43.3
10.4-11.5
11.5-12.6
12.5-13.7
Times in minutes
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
1800
1630
1540
80/26.7
1780
1620
1520
90/32.2
1750
1610
1520
100/37.8
1690
1630
1430
110/43.3
1570
1440
1340
Based on average ice slab weight of 13- 14.125 lb
Ratings with JC1395 condenser
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
-20/-28.9 to
50/10.0
250-220
44-26
110-170
65-85
70/21.1
280-240
50-28
115-180
70-90
80/26.7
290-245
50-28
115-180
70-90
90/32.2
300-250
52-28
120-195
70-90
100/37.8
340-260
60-28
125-210
70-90
110/43.3
390-295
60-30
125-220
80-100
Suction pressure drops gradually throughout the freeze cycle
Summary of Contents for S model
Page 3: ......
Page 10: ...Table of Contents continued 6 Part No 80 1480 3 ...
Page 42: ...Ice Machine Operation Section 3 3 6 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 56: ...Maintenance Section 4 4 14 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 70: ...Electrical System Section 6 6 10 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 106: ...Electrical System Section 6 6 46 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 168: ...Refrigeration System Section 7 7 62 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...