Section 7
Refrigeration System
Part Number 80-1559-3
7-19
Cycle Time/24 Hour Ice Production/
Refrigerant Pressure Charts
These charts are used as guidelines to verify correct ice
machine operation.
Accurate collection of data is essential to obtain the
correct diagnosis.
•
Refer to “OPERATIONAL ANALYSIS TABLE” for the
list of data that must be collected for refrigeration
diagnostics. This list includes: before beginning
service, ice production check, installation/visual
inspection, water system checklist, ice formation
pattern, safety limits, comparing evaporator inlet/
outlet temperatures, discharge and suction pressure
analysis.
•
Ice production checks that are within 10% of the
chart are considered normal. This is due to variances
in water and air temperature. Actual temperatures
will seldom match the chart exactly.
•
Zero out manifold gauge set before obtaining
pressure readings to avoid misdiagnosis.
•
Discharge and suction pressure are highest at the
beginning of the cycle. Suction pressure will drop
throughout the cycle. Verify the pressures are within
the range indicated.
•
Record beginning of freeze cycle suction pressure
one minute after water pump energizes.
•
50Hz production derate is 7%
S1000 SERIES
Self-Contained Water-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Air Temp.
Around Ice
Machine
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
6.8-7.9
7.4-8.6
8.5-9.8
.75-2.00
80/26.7
6.9-8.0
7.5-8.7
8.6-9.9
90/32.2
6.9-8.1
7.6-8.8
8.7-10.1
100/37.8
7.0-8.1
7.7-8.9
8.9-10.2
Times in minutes
Air Temp.
Around Ice
Machine
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
1000
930
830
80/26.7
990
920
820
90/32.2
980
910
810
100/37.8
970
900
800
Based on average ice slab weight of 5.75- 6.50lb
Condenser
Water
Consumption
90/32.2 Air Temperature
Around Ice Machine
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
Gal/24 hours
710
1500
5100
Water regulating valve set to maintain 240 PSIG discharge pressure
Air Temp.
Around Ice
Machine
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
235-245
40-24
160-175
75-90
70/21.1
235-245
40-25
160-175
75-90
80/26.7
235-250
42-26
170-185
80-95
90/32.2
240-270
48-28
175-205
85-105
100/37.8
250-280
52-28
180-210
90-110
110/43.3
250-285
54-28
185-215
95-115
Suction pressure drops gradually throughout the freeze cycle