Water Supply and Drain Requirements
WATER SUPPLY
Prepare water supply line and drain before installation of
your ice machine. Installation requires a 1/4” ID copper cold
water line and compression fitting (not supplied). The ice
machine is supplied with a drain hose for gravity draining.
The optional drain pump must be purchased if a gravity
drain is not possible. Both drain methods require routing to
an open site drain. Do not connect directly to drain line as
bacteria from drain line may contaminate the ice machine.
The included water filter is designed to inhibit scale
formation, filter sediment, and remove chlorine odor and
taste. The life expectancy of the water filter is 6 months
during normal usage. The ice machine control board will
monitor water usage and indicate when replacement is
required.
WATER INLET LINES
Follow these guidelines to install water inlet lines:
• Plumbing must conform to state and local codes.
• Do not connect the ice machine to a hot water supply.
Be sure all hot water restrictors installed for other
equipment are working. (Check valves on sink faucets,
dishwashers, etc.)
• If water pressure exceeds the maximum recommended
pressure (80 psi - 55 bar), obtain a water pressure
regulator from your Manitowoc distributor.
• Install a water shut-off valve for the ice making water
lines.
• Insulate the water inlet line to prevent condensation.
DRAIN CONNECTIONS
Follow these guidelines when installing drain lines to prevent
drain water from flowing back into the ice machine and
storage bin:
• Drain lines must have a 1.5 inch drop per 5 feet of run
(2.5 cm per meter), and must not create traps.
• The floor drain must be large enough to accommodate
drainage from all drains.
• Drain pump discharge line must terminate at an open site
drain.
• Maximum rise - 12 feet (3.7 m)
• Maximum run - 100 feet (30.5 m)
Approximate Height of Ice Machine Drain
Leg Levelers
3” (76 mm)
Installation with Leg Option
7” (179 mm)
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
Location
Water
Temperature
Water
Pressure
Ice
Machine
Fitting
Tubing Size
Up To Ice
Machine
Fitting
Ice
Making
Water
Inlet
35°F (1.6°C)
Min.
90°F (32.2°C)
Max.
Minimum
20 psi
(137.9 kPA)
Maximum
80 psi
(551.5 kPA)
1/4”
(6 mm)
OD
Copper
Tubing
1/4”
(6 mm)
Minimum
Outside
Diameter
Ice
Making
Bin Drain
---
---
3/4”
(19 mm)
Hose Barb
3/4”
(19 mm)
Minimum
Inside
Diameter
Drain
Pump
---
---
3/8”
(9 mm)
Hose
3/8”
(9 mm)
Minimum
Inside
Diameter