background image

17.03.2011     

5

 

Cleaning 

 

Do not clean the applicator with a high-pressure spray or with an intense water jet spray

 

Cleaning during the season: 

During short breaks in the work day (a few hours), the herbicide can 

remain in the system as long as the metering valve is closed. After completion of work task: before 
cleaning, return the chemical into its original container. Set the metering valve to maximum (water 
cock symbol). Fill the chemical tank half way with water, actuate the button switch and allow the 
atomiser to run for 3 minutes over a collector tank or spread the cleaning fluid over the previously 
worked surface. Remove the remaining water from the tank. 

 

Cleaning after the season:

 Rinse the unit with warm water or cleaning agent like “tankcleaner” as 

described above. The spray hood and the atomiser housing can be cleaned with a moist cloth, 
except the atomiser disc in order to avoid damage. For heavy contamination, the atomiser housing 
should be unscrewed to remove contaminants and plant parts. Connect the unit to the battery 
charger (see page 3). 

 

Charging the applicator and care of the accumulator 

The applicator is fitted with an automatic charging device. Trickle charging is possible. 

In order to charge a completely empty battery back up to full capacity, ca. 16 hours charging time is required. When a battery is 
empty, it should be immediately recharged. Never leave a battery discharged for long periods. 

 

Battery charging  

 

Minimum charging time      Time interval

 

Fully discharged    

 

           8 hrs. 

 

     immediately 

Short-term usage  

 

           3 hrs. 

 

     immediately 

Storage without usage 

 

         ( 2 hrs. 1 x per month)   

or permanent charge

 

The applicator can be used for ca. 8 hours with a fully charged battery. 

 

 

Battery and motor monitoring 

 

If the battery is fully charged the LED lights green. If the battery was 
charged for 8 hours and the monitoring LED still lights red, the 
atomiser disc might be seized. Reason for that can be insufficient 
cleaning. (see fault remedy below) 
Another reason might be a defective battery. In this case the battery 
has to be replaced. 
 
 

 

Fault remedy 

 

Fault 

 

 

Cause   

 

 

 

Remedy 

 

Atomiser disc not 

Atomiser contaminated 

 

 

Thoroughly clean atomiser, remove plant parts if needed 

turning

   

 

Battery empty 

 

 

 

Charge battery 

 

 

 

Fuse blown 

 

 

 

Replace fuse on powerpack 

 

 

 

 

 

 

 

 

(Replacement fuses are located in the powerpack 

 

 

 

 

 

 

 

 

housing) 

 

 

 

No electrical contact 

 

 

Check cable or connector contact

 

 

 

 

Battery defective   

 

 

Install new battery

 

 

 

 

Atomiser motor defective   

 

Install new motor module

 

 

 

 

 

 

 

 

 

 

Atomiser spray

   

Rotation disc turning in the wrong direction  Connect cable correctly!  

one-sided

 

 

 

 

 

 

 

Selectively plug the brown cable onto the contact pin 

 

 

 

 

 

 

 

 

on the switch/valve unit 

 

 

 

 

 

 

 

 

Connect the blue cable via the round pin plug. 

 

 

 

 

 

 

 

 

Check to ensure the battery connection to the 

 

 

 

 

 

 

 

 

powerpack is correctly poled, brown cable to Plus (+). 

 

Atomiser spray too wide

 Width adjustment improperly set 

 

Loosen the screw (F, see page 4) and correct the 

 

 

 

 

 

 

 

 

width setting to the left or to the right, respectively 

 

Atomiser drips

   

Metering valve incorrectly set 

 

Check setting, see table 

 

 

 

Atomiser disc defective / contaminated 

Replace / clean disc 

 

 

 

Atomiser spray discharge contaminated 

Clean 

 

Atomiser foams

  

Residual water in system   

 

Completely empty container, hose, segmental atomiser. 

 

Chemical not 

 

Metering valve clogged 

 

 

Set scale to maximum         . flush the unit with warm 

flowing evenly

   

 

 

 

 

 

water or use cleaning syringe 

 

 

 

 

 

 

 

 

(accessory art.-no. 100348). 

 

 

 

Breather hole of the lid is clogged   

Clean the lid with warm water 

 

Summary of Contents for HQ 30

Page 1: ...agency Application is to be performed only by a competent user Remarks about usage of the unit Settings This system is not suitable for the application of water Use herbicides for testing the spray a...

Page 2: ...scosity are suitable If you intend to use a product other than Roundup UltraMax its application should be initially tested on a trial basis over a small area In any case the usage instructions for the...

Page 3: ...PowerFlex applied Pre position Droplets per ml per applied Pre position Droplets per ml per quantity desired metering knob minute minute quantity desired metering knob minute minute 1l ha A 50 2 0 1l...

Page 4: ...sired volume can be regulated at the metering valve by setting a greater or lesser flow rate Spray width Hold the applicator in its working position above the overlay e g cardboard or paper Actuate th...

Page 5: ...charge The applicator can be used for ca 8 hours with a fully charged battery Battery and motor monitoring If the battery is fully charged the LED lights green If the battery was charged for 8 hours...

Page 6: ...width from 2007 without atomiser and spray hood bracket 102965 Screw kit MANKAR HQ 102445 Charger 100 240 6V DC 450mA NEW no pic Item Part No Description Item Part No Description 103150 Atomiser for M...

Page 7: ...le Tank cleaner and mount it 3 Set the Dosing valve to the max water tap symbol 4 Switch the unit on switch on hand grip let it run for app 3 minutes 5 Charge the MANKAR HQ with the attached charger 6...

Page 8: ...le responsibility that the following products are in conformity with the provisions of the following Council Directive 2006 42 EG Typ MANKAR HQ with 0 5 l reservoir MANKAR HQ with 1 l bottle Hiske Wei...

Reviews: