14
decreases, the user will begin to sense a slight odor or taste of the contaminant, indicating that the filter should be
replaced.
Caution:
Room air filtration units are designed to meet or exceed standards for high efficiency air filtration equipment.
Use only Mann+Hummel parts, including replacement filters.
Use of non Mann+Hummel parts and filters voids the
product warranty and all performance claims.
Warning:
To reduce the risk of fire, electrical shock or personal injury, always turn the UV lamp switch "OFF" (TRI-KLEEN
500UV BR),
turn the unit “OFF” and disconnect the power cord from supply receptacle before replacing the HEPA filter
,
HEPA filter/UV lamp assembly (TRI-KLEEN 500UV BR) and before cleaning or servicing the unit. The UV lamp produces
intense ultraviolet light and heat. Direct contact with ultraviolet light and the lamp surface can cause temporary or
permanent loss of vision and severe skin burns. Never look at a UV lamp while it is illuminated. Lamp mus
t be “OFF” for
at least 15 minutes before replacing the HEPA filter/UV lamp assembly, to allow the lamp to cool. Touching the lamp
immediately after it is turned “OFF” will result in severe skin burns
.
FILTER REPLACEMENT PROCEDURE
To change the pre-filter:
1.
With the unit turned on and running at Speed 4, open the pre-filter door by
swinging it upwards (refer to the key components section at the beginning of the
manual to locate the pre-filter door).
2.
Slide the pre-filter upwards to remove it from the pre-filter compartment.
3.
Slide in a new pre-filter, making sure the air flow directional arrow is pointing
towards the machine and that the pleats on the filter are oriented vertically
4.
Close the pre-filter door.
To change the HEPA filter (and UV lamps):
Important note
: The HEPA filter/UV lamp assembly in UV models is supplied as a unit and must be replaced as such.
Mann+Hummel recommends replacing the HEPA filter/UV lamp assembly every 12 months. The UV lamps are
permanently mounted inside the HEPA filter frame. The UV lamps itself are not replaceable.
Warning:
UV lamps get extremely hot during operation. Lamp must be "OFF" for at least 15 minutes before replacing
the HEPA filter/UV lamp assembly to allow lamp to cool. Touching the lamp immediately after it is turned "OFF" will
result in severe skin burns
1.
Turn the unit OFF and unplug the power cord from the receptacle.
2.
Disconnect any ducting from the unit and then carefully turn the machine upside down (onto its top) to gain
access to the HEPA filter access panel (refer to the KEY COMPONENTS section at the beginning of the manual to
locate the access panel). Be sure that the unit is secured so that it does not fall over during the HEPA filter
change process.
3.
Remove all of the Philips head screws located along the perimeter of the access panel (do not unscrew the
casters from this panel) and remove the access panel from the machine.
4.
Remove the nuts that secure the metal HEPA filter retaining bracket in place. Slide the bracket off the long
filter retaining bolts and carefully remove the HEPA filter.
Note:
UV lamps must be disposed of in accordance with federal, state, municipal, local and employer
regulations. Contact the local waste disposal authority for instructions on the proper disposal of UV lamps.