93
DLC Watchdog error
The drive controller monitors that the DLC is operating correctly. If the pro-
cessor system of the DLC is out of synchronization with the drive controller’s
processors, error no. 93 will be generated in the DKS.
Remedy
DLC card or drive controller defective.
94
Unacceptable software combination
The software for the drive controller in the DSM software module and in the
single-axis positioning module DLC do not match.
Remedy
1. Replace the DLC card. If the error is still present after the DLC card has
been replaced, replace the drive controller.
1. Contact INDRAMAT Customer Service.