9. Diagnostics and Fault Clearance
• DOK-CONTRL-DDC+MDD+DLC-ANW1-EN-E1,44 • 01.97
106
A PC and the emulation software DDS2PC are needed for this gauging pro-
cedure. The reference offset can be read. No calculations are needed.
Gauging:
• Connect the RS 232 interface of the drive controller (X2) with the PC. Call
up the DDS 2 PC emulation software.
• Reference the axes.
Caution
After referencing, the reference dimensions are still shifted within one motor
revolution (1 x feed constant).
• Move the axis in jog mode or manually to the marking.
• Switch parameter mode on at the DLC.
• Start the user interface of the drive controller at the PC and in menu 2
(parameter) call up submenu 2 (position evaluation).
• In submenu 2, degrees must be indicated in parameter return offset 0.
Enter 0, if necessary.
• Read rotor position and enter the current angle (e.g., 215.0313 degrees)
as the reference offset.
• Switch on setup mode at the DLC and reference the axis again.
• The axis should be located at the marker.
Marking any point
The position of the marker must be known. A CTA programming and display
unit must be connected to the drive controller. It is now possible to calculate
the reference offset.
Gauging:
• Reference axis
Caution
Source of danger:
danger of collision
Possible consequences:
Damage to the machine is possible.
How to avoid:
Remove all obstacles between the actual and the
reference position.
Measure the first workpiece after the motor has been replaced. Fine
adjustment may be necessary.
Source of danger:
Danger of collision
Possible consequences:
Damage to the machine is possible.
How to avoid:
Remove all obstacles between the actual and the
reference position.