6. Parameter Input
• DOK-CONTRL-DDC+MDD+DLC-ANW1-EN-E1,44 • 01.97
39
6.
Parameter Input
6.1.
Parameter Input Aids
Motion Manager
Using the editor and communications program „Motion Manager“ it is possi-
ble to input and secure the DLC control parameters, e.g., feed constants,
amplification of position control and so on.
DDS2PC
It is possible to access the user interface of the drive with the DDS2PC.
Such drive parameters as speed control amplification, maximum drive
speed and so on can be optimized and secured as needed with it.
CTA
All control and drive parameters can be input and optimized, as needed,
with the CTA programming display unit. The parameters are stored on the
DLC card which is backed up by a lithium battery with a lifespan of approxi-
mately ten years.
Parameter Input
The user interface of the programs „Motion Manager“ and „DDS2PC“ make
it easy to input all parameters.
How to handle the programming and CTA display unit when inputting para-
meters is described in the following section.
Source of danger:
Parameters can be cleared.
Possible consequences:
Extensive machine down times.
How to avoid:
Secure data outside of the drive.
The parameters can be stored on either disk or hard drive with the
use of the „Motion Manager“ and the „DDS2PC“. These can then be
printed out in the form of a parameter list. We recommend filing a
parameter list with the machine documentation.