7. Commissioning
• DOK-CONTRL-DDC+MDD+DLC-ANW1-EN-E1,44 • 01.97
66
DLC Error Messages
Fig 7.4: List of DLC error messages
Setting error reaction
• Switch operating mode parameter on
• with
select parameter block
• call up parameter C008
• input error reaction
• press
The errors that are detected in the DLC single-axis positioning mo-
dule (error in the position control loop), are always braked to a
standstill at maximum possible motor torque regardless of the er-
ror reaction which has been set. Power is not shutdown.
List of the DLC Error Messages
absolute encoder error
no power
axis switched off 1
maximum limit switch 1
axis number incorrect
maximum override A1
W-Dog drive
minimum limit switch 1
battery empty
positive feedback
operting mode
not setup 1
division error
E-stop
DPR illegible
zero point switch 1
store block number
parameter loss
external encoder
position monitoring 1
error input parameter
program loss
HOM - command A1
RTS nesting
IDS break error
SAC command
IDS format length
lag error
IDS format sign
software combination
IDS checksum error
a non-permissible block
illegal command
feed monitor 1
JSR nesting
WRITE command
no BCD Input
target position < limit 1
configuration
target position < limit 1
no zero pulse 1
system error 1