8. Functions of the DLC Single-Axis Positioning Module
• DOK-CONTRL-DDC+MDD+DLC-ANW1-EN-E1,44 • 01.97
84
Example: Parameter B 012
8.7.
Speed Override
The speed can be reduced to increase the control of the program sequence
whilst setting up the machine.
Override active
Speed override can generally be activated via a parameter or in the program
by means of a command.
Caution
0 7 1 1 1 1 0 0
Start block for the interrupt program
Feed interrupt yes/no
0 = Feed in progress is not interrupted (do not pro-
gram feed in the interrupt program).
1 = Feed in progress is interrupted.
Interrupt in subprogram
0 = subprogram not interrupted
1 = subprogram interrupted
A positive edge at this input (01 ... 37) starts the
interrupt program;
00 = interrupt function not active
1. There is no automatic return to the interrupted main program.
2. The interrupt vector is only available in Task 1.
3. Jumping is not possible in a subprogram that is concluded with
RTS.
Source of danger:
Speed override is not in effect during referencing.
Possible consequences:
Machine damage is possible.
How to avoid:
If necessary, reduce homing speed in parameter A
110.