8. Functions of the DLC Single-Axis Positioning Module
• DOK-CONTRL-DDC+MDD+DLC-ANW1-EN-E1,44 • 01.97
85
Override via parameter
A general speed override can be activated via parameter B 013. Speed
value input is binary or Gray-Code and a step switch mechanism is used.
Parameter B013
Fig 8.14: Speed overrride via a Gray-Code switch
Table of values with
Gray-Code speed
override
Fig 8.15: Table of values with Gray-Code speed override
Speed reduction relates to the speed which has been programmed.
6 0 0 0 0 0 0 0 0
5 = binary code
6 = Gray-Code input 04 ... 07
+24 V
Gray coded
stage switch
DEA 4.1
E04
E05
E06
E07
12
13
14
15
1
16
X17
FPgesw
Drive controller
Input
Speed in %
04
05
06
07
0
1
1
0
0
0
1
1
0
0
0
0
0
0
0
0
0
1
2
4
0
1
1
0
1
1
0
0
1
1
1
1
0
0
0
0
6
8
10
20
0
1
1
0
0
0
1
1
1
1
1
1
1
1
1
1
30
40
50
60
0
1
1
0
1
1
0
0
0
0
0
0
1
1
1
1
70
80
90
100