9. Diagnostics and Fault Clearance
• DOK-CONTRL-DDC+MDD+DLC-ANW1-EN-E1,44 • 01.97
99
88
Error reading motor data
All motor data are stored in a data memory in the motor feedback. An error
has occurred while reading these data.
Remedy
1. Defective motor feedback cable.
2. Defective motor feedback.
89
Motor data invalid
Remedy
No data or invalid data in EEPROM .
90
Error while writing motor data
An error has been detected while writing data to the motor feedback.
Remedy
1. .Defective motor feedback cable.
2. Defective motor feedback.
91
Configuration error
Remedy
1. Software and hardware configurations do not match.
2. Plug-in module defective, not installed or not properly inserted.
3. Break in feedback lead.
92
Absolute encoder not calibrated
Parameter “homing position” and/or "counting direction" in the menu “ABSO-
LUTE ENCODER PARAMETER” could not be read.
Remedy
1. These parameters have not yet been entered.
2. Feedback defective.
1. Check motor feedback cable and replace, if necessary.
2. Replace motor.
1. Rewrite EEPROM, contact INDRAMAT Customer Service.
1. Check motor feedback cable and replace, if necessary.
2. Replace motor.
1. Check the drive controller against its configuration data sheet and, if
necessary, replace the software or hardware.
2. Check plug-in module.
3. Check feedback lead.
1. Enter or confirm parameters.
2. Replace motor.