2. Components of Digital AC Servo drives with a DLC Single-Axis Positioning
• DOK-CONTRL-DDC+MDD+DLC-ANW1-EN-E1,44 • 01.97
13
2.3.
Software Module
Parameters, stored in the software module, are implemented for matching
the drive controller to the motor and the mechanical system of the machine.
Fig 2.5: A DSM 2. software module
Advantages when
replacing equipment
Operating software and drive parameters are stored on the DSM software
module. This means that in the event that a unit must be replaced it is not
necessary to re-tune the replacement. Simply remove the software module
from the faulty drive and install it on the new replacement unit. This configu-
res the drive for motor and machine.
Duplication
Software modules can be duplicated for additional identical machines or to
back up the parameters. This is done over a serial interface.
Standard software
module
The drive-specific parameters determined by INDRAMAT are stored in the
feedback of the MDD motors and are activated during commissioning as
needed.
The user-specific parameters are set on-site on the machine to the
machine-dependent values.
Compatibility of
sotware modules
The latest engineering revision level (software module update) used for ope-
rating the drive will be shipped without a change in the order numbers, i.e.,
the type codes becoming necessary. New software modules are compatible
to those already shipped.
PZDSM
DSM 2.1-C11-01RS
DSM 2.1
SN . . . . . . . . . .- . . . A00S02
Software version
Serial number
Abbreviation
Type of software module
Barcode
It is the responsibility of the customer to document and manage the
user-specific parameter values.