2. Components of Digital AC Servo drives with a DLC Single-Axis Positioning
• DOK-CONTRL-DDC+MDD+DLC-ANW1-EN-E1,44 • 01.97
14
2.4.
Auxiliary Plug-In Cards
The following plug-in cards have been summarized under the heading of
"Auxiliary Plug-In Cards".
Input/output interfaces
Type: DEA 4.1, DEA 5.1 and DEA 6.1
These plug-in modules each have 15 inputs and 16 outputs with which the
drive can exchange binary signals.
Different addresses are set on each card.
The DEA 4.1 has eight inputs and five outputs for functions such as E-stop
input, signalling of operating mode and fault messages. Still available are
seven inputs and eleven outputs.
Interbus S interface
module
Type: DBS 2.2
With the interbus S DBS 2.2 interface module, the drive is connected to an
interbus S data highway. The DBS 2.2 can only be used in conjunction with
the single-axis positioning module
DLC 2.1
. The operating modes target
position entry and local operations are possible. In local operations, it is pos-
sible to replace the physical I/O level with the interbus S interface module.
Fig 2.6: Auxiliary plug-in cards
2.5.
Configuration Rating Plate
The type designation is on the configuration rating plate:
• the configured drive controller
• the basic unit
• the software module in slot U5
• the plug-in modules in slots U1 through U4
With the use of this type designation, it is possible to determine which com-
ponents should be in which slots.
In the event of a problem, the information on the rating plate can be used to
quickly locate a replacement for the problem part or a new basic unit can be
quickly fitted. A replacement unit is obtained by inserting the specifically
required modules into the basic unit specified on the rating plate.
DEF 1.1
DLC 1.1
X 31
X 30
DBS 1.1
X38
X37
H1
H2
H3
H4
RB
BA
RC
ME
FAzumod
DEA
4.1
Type
DEA
DEF
DLC2.1
Type
DBS2.2
Type
Type