RELEASABLE BOND—RESIDENTIAL AND LIGHT COMMERCIAL

Application- Better

 

This method is viable for concrete and most wood panel substrates in climate controlled, occupied, existing homes. 

(Unconditioned wood panel substrates are not dimensionally stable and are subject to too much movement.) Check the 

porosity of the subfloor and, if necessary, use Mannington’s Premium Universal Primer to prevent over absorption of adhesive. 

To achieve a Releasable Bond, the MT- 711 is applied over the substrate with a 3/8 nap paint roller and allowed to dry to tack 

before positioning the 

Insight

®

 Plus GB

 into the adhesive. The 

Insight

®

 Plus GB

 is then positioned into the dry “tacky” 

adhesive, next using a clean, soft-bristle push broom, smooth the material in both directions, starting in the middle of the 

sheet width and working toward the edges.

Because of the thin, dry adhesive film, this method can be used with many types of substrates including clean, lightly 

embossed resilient flooring without the use of a leveler and over clean, dry and smooth OSB substrates without extraordinary 

floor prep. The coverage rate of the MT-711 adhesive will be increased to approximately 300 square feet per gallon when 

applied with a paint roller. 

Regardless of the method 

Insight

®

 Plus GB

 must always be trimmed back (1/8” to 1/4”) from all fixed vertical surface and 

must be fit with no compression or fullness. Under cut all door casings and be certain the material is positioned true and 

square in the work area. 

FULLY ADHERED-RESIDENTIAL AND COMMERCIAL

Application- Best

Permanent Bond: This method is the most secure and best if there is heavy foot or rolling traffic or if the layout is complicated. 

Because the Permanent Bond is achieved by placing the 

Insight

®

 Plus GB

 into the wet-tacky MT-711 adhesive with a 

1/16”x1/32”x1/32” notched trowel, the substrate must be smooth and have sufficient porosity to receive the adhesive. For 

wood substrates, in most cases this requires the use of an appropriate underlayment. A concrete surface must be smoothed 

using an appropriate Portland cement patching compound. Installation over existing resilient or ceramic floors requires and 

embossing leveler. Additionally, the 

Insight

®

 Plus

 should be rolled in both directions with a 50 lb., (or heavier) three section 

roller. 

Note: 

Mannington’s V-88 adhesive is an option in areas where a high moisture adhesive is needed. When installing 

homogenous sheet vinyl with V-88 adhesive it is recommended to trowel the adhesive then back roll with a short-nap paint 

roller to minimize the possibility of trowel ridge telegraphing.  V-88 can only be used in permanent, full spread installation 

method.

When used in a Commercial application all previous flooring materials must be thoroughly removed and adhesive scraped up 

and cleaned before installation of the 

Insight

®

 Plus GB

 flooring. The floor must be smooth, level, and flat.              

 Recommended Use Chart

Residential- R
Commercial- C

Loose Lay

Good

Releasable Adhesive

MT- 711- roller

Better

Permanent Adhesive

MT-711- trowel

Best

Spacing (Gap) at vertical surfaces

1/8”- 1/4”

1/8”- 1/4”

1/8”- 1/4”

Yardage allowed per room

30 sq yds total

R-C

Unlimited

R-C

Unlimited

R-C

Structures on flooring

No

R-C

Yes

R

Yes
R-C

Seams allowed

1 per room R-C

Multiple

R-C

Multiple

R-C

Rooms with Floor Drains

No

R-C

No R-C

Yes
R-C

Bathrooms

Yes 

NO SEAMS R-C

Yes
R-C

Yes
R-C

Rolling Loads

No

R-C

No

R-C

Yes
R-C

Pivot Points

Minor

moderate

Yes
R-C

Flash Coving

No

No

Yes

Choices that Work.

Questions about warranties? call 800 241 2262 or visit www.manningtoncommercial.com 

July, 2015 

Insight

®

 Plus GB

Installation Guidelines

Insight

®

 Plus GB Instal

lat

ion Guidel

ines

Summary of Contents for Insight Plus GB

Page 1: ...materials for subfloor preparation MATERIAL RECEIVING HANDLING STORAGE 1 Always store Insight Plus GB tightly rolled face out on a sturdy cardboard core designed for that purpose Store the roll horizo...

Page 2: ...can Corp 757 425 1206 www koesterusa com Mapei 800 426 2734 www mapei com Uzin Ltd 800 505 4810 www ufloorsystems com SUBFLOOR PREPARATION Concrete Careful subfloor preparation is vital for an excelle...

Page 3: ...ess Have a written warranty for suitability and performance from the panel manufacturer or have a history of proven performance e Any unevenness at the joints between panels must be sanded to a level...

Page 4: ...placing the Insight Plus GB into the wet tacky MT 711 adhesive with a 1 16 x1 32 x1 32 notched trowel the substrate must be smooth and have sufficient porosity to receive the adhesive For wood substr...

Page 5: ...o the adhesive to eliminate trapping air Do not drop or flop the material into the adhesive Using a 50 lb or heavier three section floor roller roll the material in both directions starting in the mid...

Page 6: ...n determining the direction of sheet or fill piece if needed REVERSE METHOD Reverse Sheets for Seaming means turning the second sheet 180 to the first sheet To determine the amount of additional mater...

Page 7: ...ong the length of the seam You must apply seam sealer into the seam cut and leave a bead of sealer approximately 1 8 wide centered on the seam Remember it is crucial that the seam sealer be applied to...

Page 8: ...deep If the Insight Plus GB was installed FULLY ADHERED apply a thin layer of MT 711 to the back of the repair piece and place into position Roll with a hand roller Apply MLG 33 seam sealer Protect f...

Reviews: