background image

 

 

4

TIMER ADJUSTMENT 

 

BEFORE  ADJUSTING  THE  TIMER,  SWITCH  OFF  THE  MAINS  SUPPLY.  TIMER  SHOULD 
ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION. 

 

1.  Remove  the  fan  grille.  The  controller  is  factory  set  at  15  minutes  approx.  The  overrun  time  period  can  be 

adjusted from 5-25 minutes by altering the adjuster on the control PCB. 

2.  To REDUCE the operating time, use a small screwdriver to turn the adjuster Fig.4. ANTI-CLOCKWISE.  

3.  To INCREASE the operating time, use a small screwdriver to turn the adjuster Fig.4. CLOCKWISE. 

4.  Replace the fan grille. 

C.  HUMIDISTAT / SHUTTERED HUMIDISTAT TYPE 

 

The fan contains an integral humidity controller. In automatic mode the controller switches the fan on at full speed 
when the room Relative Humidity (RH) reaches the set-point. The fan will continue to run until the room RH falls 
below  the  set-point.  Fig  5.  These  fans  may  also  include  a  built  in  timer  function.    The  timer  can  be  activated  by 
removing the jumper JP1,  This will give the fan a fixed over run time of approx. 15 mins. 

HUMIDITY SET-POINT ADJUSTMENT 

 

BEFORE ADJUSTING THE CONTROLLER, SWITCH OFF THE MAINS SUPPLY. HUMIDISTAT 
SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION. 

 

1.  Remove the fan grille. The controller is factory set to switch on at about 70% RH. The humidity set point can be 

adjusted from 65-95%RH by altering the adjuster on the control PCB. 

2.  To  LOWER  the  set-point  use  a  small  screwdriver  to  turn  the  adjuster  Fig.5.  ANTI-CLOCKWISE.  This  makes 

the controller MORE sensitive.  

3.  To  RAISE  the  set-point  use  a  small  screwdriver  to  turn  the  adjuster  Fig.5.  CLOCKWISE.  This  makes  the 

controller LESS sensitive.  

4.  Replace the fan grille. 

NOTE! DO NOT TOUCH HUMIDITY SENSOR. 

Shutter Operation 

With  the shuttered  fan types the shutters will open  immediately  when the fan  is  turned on. The shutter  will close 
immediately after the fan is switched off. The shutters are positioned at the rear of the product and cannot be seen 
from the front. 

 
 

 
 
 
 

 
 
 
 
 

 
 

This product should not be disposed of with household waste.  Please recycle 
where facilities exist.  Check with your local authority for recycling advice. 

 
 

 
 

 

 

PO BOX 1285 GB

 

449726B 

 

 

 

 

 

 

 

       

1116

 

Summary of Contents for SLIM F100

Page 1: ...0 16 IP44 F100TS 1 2 3 220 240 50 16 IP44 F100HS 1 2 3 220 240 50 16 IP44 F150 1 2 3 220 240 50 16 IPX4 F150S 1 2 3 220 240 50 16 IPX4 F150T 1 2 3 220 240 50 16 IPX4 F150TS 1 2 3 220 240 50 16 IPX4 F150HS 1 2 3 220 240 50 16 IPX4 H models Humidity Adjustment I To activate the timer function remove jumper JP1 If fitted Once removed the fan will run on for a fixed period of approx 15 mins T models T...

Page 2: ...F The fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time G Where ducted fans are used to handle moisture laden air a condensation trap should be fitted Horizontal ducts should be arranged to slope slightly downwards away from the fan H This appliance is not intended for use by persons including children with reduced physical sensory or menta...

Page 3: ...nd cement both ends into position flush with the wall faces 2 Loosen the screw in the bottom of the grille and remove the front grille Mark the screw centres through the holes in the fan back plate Drill plug and screw into position Fix exterior grille into position with the louvres positioned downwards Note The grille must comply with the standard requirements of your country to prevent access to...

Page 4: ... the fan a fixed over run time of approx 15 mins HUMIDITY SET POINT ADJUSTMENT BEFORE ADJUSTING THE CONTROLLER SWITCH OFF THE MAINS SUPPLY HUMIDISTAT SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION 1 Remove the fan grille The controller is factory set to switch on at about 70 RH The humidity set point can be adjusted from 65 95 RH by altering the adjuster on the control PCB 2 To LOWER the se...