USE AND CARE GUIDE

CHECK THE WATER WHEN YOU BEGIN FILLING TO ENSURE IT IS AT A SAFE TEMPERATURE.

Congratulations on the purchase of your new walk-in tub.  By carefully following your new walk-in tub’s 

instructions, you can benefit from the safety, dignity, independence and a tremendously improved quality 

of life. 

Please read the following instructions before using your walk-in bath and retain for future reference.

Proper door handle use: 

Even though the handle is fabricated from the strongest materials available it will not withstand use of 

excessive force to close the door or use as a grab bar.  If used in either of these ways the bottom of the 

handle may break away from its fixing.  The handle is designed as an opening and closing mechanism for 

the door.

Using your Walk-in Tub

RESTORE ACR General Instructions

Enter the bath and sit if desired. Next, close the door and seal it by pushing the handle forward into the 

locked position. Close the drain by turning the handle at the overflow counter clockwise.  With the pre-set 

thermostatic mixing valve (professionally installed by your plumber) it is only necessary to turn on the hot 

water.  However, if a cooler bath is desired, turn on the cold water to mix with the hot water.  Fill the bath to 

a depth to best suit your needs.  When the bather is done, drain the bath by turning the handle clockwise.

After the bath is fully drained, open the door by pulling backward on the door handle and carefully exit the 

tub.

RESTORE Air Bath – Model 8490 or 8590

IMPORTANT 

It is recommended that bathers should limit their use of the air system to not more than 20 minutes in any 

one bathing session.

OPERATION
BUTTON 1, WHITE LIGHT - POWER ON/OFF

  The first button is the power button which will activate the 

keypad and illuminate in dim colors.

BUTTON 2, BLUE LIGHT - BLOWER

  Push 

the button once to activate blower, push 

again to turn off.

BUTTON 3, YELLOW LIGHT - LIGHT 

 

SYSTEM

 Push the button once to activate 

the light system.  Continue to push button 

until desired color is reached or lights are 

turned off.  Push and hold button for two 

seconds to power off immediately.

BUTTON 4, RED LIGHT  - SURFACE HEATER 

(if equipped)

  Push the button once to activate the heated seat and backrest, push again to turn off.

NOTE:
BLOWER TIMER

 - The system is equipped with a 20 minute timer.  The blower will turn off automatically 

after the time has elapsed.

PURGE AND DRY CYCLE

 -  A one minute purge and dry cycle will activate 20 minutes after the Blower 

is turned off.    When the bather is finished, the water should be drained. The blower will reactivate 20 

minutes after it is turned off and will run for one minute.  The blower will turn back off after one minute.

Summary of Contents for Restore ACR 8090

Page 1: ...I M P O R TA N T H O M E O W N E R I N F O R M AT I O N Installation Use and Care Guide RESTORE ACR LUXURY WALK IN BATHTUB...

Page 2: ...OUTES MUNIES D UNE GRILLE 6 WARNING TO AVOID INJURY EXERCISE CARE WHEN ENTERING OR EXITING THE HYDROMASSAGE BATHTUB and AVERTISSEMENT POUR EVITER LES BLESSURES USER DE PRUDENCE EN ENTRANT DANS LA CUVE...

Page 3: ...N CLEAN TO MINIMIZE SLIPPAGE 20 SOAKING TOO LONG MAKES SOME PEOPLE NAUSEOUS DIZZY LIGHT HEADED OR FAINT DON T SOAK FOR MORE THAN 15 MINUTES IN 104 FAHRENHEIT WATER IF YOU WISH TO SOAK FOR A LONGER PER...

Page 4: ...nnections as appropriate Do not alter the door fittings tamper with the hinge or try to get a closer fit on the seal DO NOT OVERTIGHTEN ANY BOLTS The baths are completely water tested prior to leaving...

Page 5: ...ice has been installed at the pump location See electrical requirements below ELECTRICAL REQUIREMENTS ELECTRICAL REQUIREMENTS Equipment utilized on these baths requires individual dedicated electrical...

Page 6: ...ng the ground 5 If the product is a whirlpool or an air bath carry out any electrical work that may be required Make the electrical connections per current regulations per aforementioned electrical re...

Page 7: ...ke sure your plumber installs a thermostatic mixing valve TMV Not Supplied Connect the hot and cold water supplies to the thermostatic mixing valve Next connect the mixed hot water outlet from the hot...

Page 8: ...or silicone sealant 3 ETL CSA IAPMO and UL require a tile flange to be installed in accordance with local building codes The tile flange kit is sold as an option 1 The extension box is cosmetic and is...

Page 9: ...ELECTRICAL WIRING DIAGRAMS DUAL LOAD CONTROL MODELS 8090 8190 8490 8590 8690 and 8790 WITHOUT SURFACE HEATERS...

Page 10: ...ELECTRICAL WIRING DIAGRAMS MASTER BATH CONTROL MODELS 8090 8190 8490 8590 8690 and 8790 WITH SURFACE HEATERS...

Page 11: ...EN INLINE HEATER IS INSTALLED ON PRODUC ON PRODUCT TO CONTROL To 120V 20 AMP GFCI PROTECTED RECEPTACLE NOTE 15 AMP FOR CANADA OZONE PUMP MOTOR 8 COPPER BONDING WIRE HEATER PRE WIRED CORD PLUG PRE WIRE...

Page 12: ...ELECTRICAL WIRING DIAGRAMS MICRODERM THERAPEUTIC BATH MODELS 8890 and 8990...

Page 13: ...the bath to a depth to best suit your needs When the bather is done drain the bath by turning the handle clockwise After the bath is fully drained open the door by pulling backward on the door handle...

Page 14: ...e bathing session OPERATION BUTTON 1 WHITE LIGHT POWER ON OFF The first button is the power button which will activate the keypad and illuminate in dim colors BUTTON 2 BLUE LIGHT PUMP Push the button...

Page 15: ...nd air bath systems require routine cleaning to sanitize the system Twice per month or more depending on usage clean the whirlpool by following the directions below a Fill the tub with hot water b Add...

Page 16: ...such delays or failure is due directly or indirectly to acts of God war including civil war riots embargoes acts whether sovereign or contractual of civil or military authorities acts of any governme...

Reviews: