9.
SPECIFICATIONS
Battery Voltage System
12V System
24V System
Isolator Setting
Default
Range
Default
Range
Connect Voltage
13.7VDC
9.2 - 16VDC
27.4VDC
18.4 - 32VDC
Isolate Voltage
12.8VDC
9 - 15.8VDC
25.6VDC
18 - 31.6VDC
Alert Voltage
12.0VDC
9 - 15.9VDC
24.0VDC
18 - 31.8VDC
Connect Delay
5 seconds
1 - 250 seconds
5 seconds
1 - 250 seconds
Isolate Delay
5 seconds
1 - 250 seconds
5 seconds
1 - 250 seconds
Alert Delay
10 seconds
1 - 250 seconds
10 seconds
1 - 250 seconds
Isolator Setting Accuracy
±
0.2V
Resolution
0.1V 1 seconds
Operating Voltage
9 - 17VDC Nominal
18 - 34VDC Nominal
Continuous Contact Current
120Amp
Current draw in Isolate Mode
Less than 30mA (add appox. 20mA when LED display is active)
Current draw in Combine Mode
Less than 50mA (add appox. 20mA when LED display is active)
Voltage drop with 120A
(Main battery to Aux. battery)
130mV
Protections
System Under Voltage
Disconnect (Auto reconnect when condition returns to normal)
System Over Voltage
Disconnect (Auto reconnect when condition returns to normal)
System Overload and Short Circuit
Disconnect (complete reset by disconnect and reconnect the battery)
Unit Over Temperature
Disconnect (Auto reconnect when condition returns to normal)
Advance Feature
Ignition Control
Yes (Default as OFF)
Normal Open/Close (N.O./N.C.)
Yes (Default as normal open)
Remote Alert Provision for LED Indication
Yes (System Voltage, 100mA Max.)
Conditional Manual Over-ride (connect) Mode
Yes (Remote Input +12VDC)
Yes (Remote Input +24VDC)
Operating Temperature Range
-20
°
C to +60
°
C
Operating Humidity
10% to 90% RH non-condensing
Environmental Protection
(Internal Component only)
IP67
Approval
CE
Supplied Accessory
Remote LED Module with Over-Ride and 2M Cable,
one 400V 3A Diode
Dimensions (L x W x H)
90 x 90 x 85 mm (3.5 x 3.5 x 3.4 inch)
Weight
0.6kg (1.3lbs)
REV.0 09/2017
7673-6113-0580