background image

9. 

SPECIFICATIONS

 

 

Battery Voltage System 

12V System 

24V System 

Isolator Setting 

Default 

Range 

Default 

Range 

Connect Voltage 

13.7VDC 

9.2 - 16VDC 

27.4VDC 

18.4 - 32VDC 

Isolate Voltage 

12.8VDC 

9 - 15.8VDC 

25.6VDC 

18 - 31.6VDC 

Alert Voltage 

12.0VDC 

9 - 15.9VDC 

24.0VDC 

18 - 31.8VDC 

Connect Delay 

5 seconds 

1 - 250 seconds 

5 seconds 

1 - 250 seconds 

Isolate Delay 

5 seconds 

1 - 250 seconds 

5 seconds 

1 - 250 seconds 

Alert Delay 

10 seconds 

1 - 250 seconds 

10 seconds 

1 - 250 seconds 

Isolator Setting Accuracy 

±

0.2V 

Resolution 

0.1V    1 seconds 

 

Operating Voltage 

9 - 17VDC Nominal 

18 - 34VDC Nominal 

Continuous Contact Current 

120Amp 

Current draw in Isolate Mode 

Less than 30mA (add appox. 20mA when LED display is active) 

Current draw in Combine Mode 

Less than 50mA (add appox. 20mA when LED display is active) 

Voltage drop with 120A 
(Main battery to Aux. battery) 

130mV 

Protections

 

System Under Voltage 

Disconnect (Auto reconnect when condition returns to normal) 

System Over Voltage 

Disconnect (Auto reconnect when condition returns to normal) 

System Overload and Short Circuit 

Disconnect (complete reset by disconnect and reconnect the battery) 

Unit Over Temperature 

Disconnect (Auto reconnect when condition returns to normal) 

Advance Feature

 

Ignition Control 

Yes (Default as OFF) 

Normal Open/Close (N.O./N.C.) 

Yes (Default as normal open) 

Remote Alert Provision for LED Indication 

Yes (System Voltage, 100mA Max.) 

Conditional Manual Over-ride (connect) Mode 

Yes (Remote Input +12VDC) 

Yes (Remote Input +24VDC) 

 

Operating Temperature Range 

-20

°

C to +60

°

Operating Humidity 

10% to 90% RH non-condensing 

Environmental Protection 
(Internal Component only) 

IP67 

Approval 

CE 

Supplied Accessory 

Remote LED Module with Over-Ride and 2M Cable, 
one 400V 3A Diode 

Dimensions (L x W x H) 

90 x 90 x 85 mm (3.5 x 3.5 x 3.4 inch) 

Weight 

0.6kg (1.3lbs) 

 
 

REV.0  09/2017 

7673-6113-0580 

Summary of Contents for SSB-6113

Page 1: ...te sparks near battery or protector during normal operation as batteries may give out explosive gas Do not use the protector if it has been dropped or damaged Do not remove casing of the protector the...

Page 2: ...nitoring finer tuning of voltage delay timer set points and more fail safe protection with diagnostic display 2 Advanced Features Alert Voltage The additional Alert Voltage setting is to monitor the m...

Page 3: ...are version to confirm setting then the battery voltage If no selection is done within 10sec unit will go back to last set system voltage Remark You have about 10 seconds to confirm your setting other...

Page 4: ...Set Mode 2 automatically after 20 seconds with the new settings N O N C Application MODE Normally Open This is the factory default mode The two terminals are normally isolated disconnected open when t...

Page 5: ...protection will lock up the unit until complete reset by disconnect and reconnect the battery Over Temperature Protection Unit Over Temperature 90 C Check location of unit is well ventilated Check cab...

Page 6: ...he spot which is powered up when the Ignition switch is on A External Alert Alarm port An external signal voltage to indicate the operation status of the unit It synchronizes with the Alert Voltage an...

Page 7: ...above control port Neg A R Black wire to Neg Negative ground Red wire to Main terminal Remote Override function Green wire to R Remote Override function Yellow wire to A LED indicator Remark If no int...

Page 8: ...n battery to Aux battery 130mV Protections System Under Voltage Disconnect Auto reconnect when condition returns to normal System Over Voltage Disconnect Auto reconnect when condition returns to norma...

Reviews: