background image

 

 

 

 

  WARNING: 

important safety instructions. 

These instructions must be followed in the interest of personal safety; Keep 
these instructions. 

 

WIBAT is exclusively designed for opening and closing swing shutters. It must not be used for any 
purpose other than that specified in these instructions. The manufacturer or supplier shall not be liable 
for any damage resulting from improper use thereof. The user alone shall be solely liable and assume 
any risks arising from improper use of the product. 
 
This shutter motor must be installed by persons fully aware of the hazards involved in currents, 
drilling and chemical sealing who have the requisite qualifications to work on domestic installations 
in accordance with good practice. 
 
Follow all the instructions because faulty installation can cause injury. 
The assembly steps must be followed, as must the operating instructions, and safety rules must 
always be heeded. 
Before installing the shutter motor, check that both the driven part and the entire WIBAT are in good 
physical condition and that the structure has the necessary load-bearing capacity for the WIBAT in its 
entirety. 
 
The electrical installation must be done according to prevailing national standards and in accordance 
with all legal obligations and/or prevailing obligations to that effect. 

(Electrical compatibility: voltage and frequency as marked on the product and that of the power 
network where it will be used.) 

Do not connect the device without first checking that the control 

circuit is dead. 
 
Check the installation frequently to detect any imbalances or signs of wear or damage. Do not use 
the device if it needs repairing or adjusting. 
Disconnect the power supply when cleaning it or carrying out other maintenance or servicing 
tasks. 
 
Never modify or fit any additional parts to the device that may compromise safety without MANTION 
SMT's written permission. 
 
Be very careful not to get your fingers caught when using the device. 
The user alone is solely and entirely responsible for any breach of these safety rules, and any 
damage resulting therefrom. 
 
The product must be stored indoors in a dry place at a temperature of between 0°C and +45°C. 
When fitting it, the installation engineer must heed accident prevention instructions and the 
standards in force in the country. 

 

Do not immerse the gear motor in water or splash it. 
Do not dispose of it in fire or bring it into contact with flame or any heat source.  
Do not use household products or chemicals to clean it. Only use a moist sponge and soap.  
Do not dispose of the packaging in the environment; treat waste according to the standards in 
force in the country

.

 

 

Keep products, devices and documentation out of reach of children. 
Do not let children play with the fixed control devices. Keep remote controls out of reach of 
children. 
When using a switch without a lock, make sure everyone else is kept at a distance. 
 
Use only the MANTION SMT-approved embedding kit and drilling equipment. 

Summary of Contents for SMT WIBAT

Page 1: ...1 INSTALLATION INSTRUCTION Product WIBAT VERSION EN 3 09 ANG 2 rue des M tiers 21110 Genlis T l 33 03 80 37 85 71 Fax 33 03 80 37 88 61 http www mantion smt fr...

Page 2: ...nd that of the power network where it will be used Do not connect the device without first checking that the control circuit is dead Check the installation frequently to detect any imbalances or signs...

Page 3: ...s not a toy do not let children play with it Keep it out of reach of children and animals Terms of the guarantee MANTION SMT products come with a 5 five years guarantee from the date of delivery The g...

Page 4: ...tation speed 1 9 rpm Opening or closing time limit 18 s Temperature to be used at 30 70 degrees C Colour Black other colours on request NB All of the data in the table is by way of indication dependin...

Page 5: ...1 5 mm 2 and 3 x 0 75 mm 2 1 Electrical box 60 mm depth hard wired version 1 concrete drill bit length according to wall thickness 1 Dispenser for chemical sealing 1 Sealing kit with mesh sleeves Mot...

Page 6: ...eding to the installation of the WIBAT When the hinges have been removed it is necessary to re block the holes left B CHOICE OF HINGES TO MECHANISE It is recommended to align stoppers with motorizatio...

Page 7: ...HINGES a Disassemble the shutters and mark the drilling site 20 mm from the edge of the strap hinge b Drill the strap hinges with a 6 5 mm drill bit right through and very perpendicular to the shutte...

Page 8: ...hinge of the shutter and draw in the area to be drilled with a pencil 4 DRILLING OF THE WALL A Remove the shutters Use the rotary comb hammer on drilling only position Do not use it on Hammer position...

Page 9: ...r sheathing Clean tidily the holes with a vacuum cleaner and a metallic brush The chemical seal doesn t adhere on dust 5 SETTING UP OF THE MECHANISED HINGE A Unscrew the two mounting screws 13 Take th...

Page 10: ...g WIBAT and the fitting box guard in the hole Make penetrate the sheath in the box guard In case the wall is porous and to avoid water seepage through the back of the product MANTION SMT recommended t...

Page 11: ...motor several times to twist the wires and get up again to the case E SHUTTERS INSTALLATION Position the rings 4 on the 2 hinges and readjust the shutters in place Fix the hinges motorized on the str...

Page 12: ...12 6 SEALING Pay attention to the correct vertical alignment of the hinges...

Page 13: ...the mesh sleeve then distribute 3 other blows while returning towards the wall Make this operation in the 4 holes envisaged to this end 5 Add the chemical seal around the fitting box in order to fill...

Page 14: ...acing silicone seal around the periphery of the protective flange 8 7 ASSEMBLY OF THE SHUTTER ON THE MECHANISED HINGES a Dismount the shutters b Withdraw the ring 4 c Mount back the shutters d Apply t...

Page 15: ...or the hard wired kit attach a 60 mm deep flush fitting box to the inside of the house and connect the wires as shown in the cabling diagram 2 Radio The casing can be installed at your liking in the f...

Page 16: ...s well as any obligations foreseen by the law and or by all obligations in force laid down for this purpose Electrical connection must take place without voltage Do not connect the sector before havin...

Page 17: ...17 ELECTRICAL CONNECTION HARD WIRED VERSION Wires for switch Feed not supplied Motor 1 Motor 2 230 V 24 VDC 2 x 1 5 2 x 0 75 Identification of motor 1 Motor 1 mechanises the covered flap...

Page 18: ...f motors Be careful to the polarity of the engines Following model If your WIBAT is intended for the mechanisation of a single flap shutter it is absolutely essential to connect it on motor 1 12 White...

Page 19: ...19 Feed connection Alimentation 24 V DC 10 24 V 230 V Connecting the power supply should meet the recommendations of the manufacturer thereof Feed not supplied Feed 24 V DC 10...

Page 20: ...ne of the two cavities located below the button Releasing the button the wire is then clamped in the cavity Check by gently pulling on it Reiterate handling for each of the three wires Radio switch co...

Page 21: ...close The Led blinks during all this cycle During the closing shutter 2 is shifted 6 secondes compared to shutter 1 When the shutter is close and the Led is no longer flashing the system is operation...

Page 22: ...ode 2 While the LED is on and not flashing press the open and close buttons simultaneously on the switch The LED flashes quickly then goes out the switch is now peered Peering a remote control 1 Press...

Page 23: ...ons simultaneously for the desired channel on the remote control The LED flashes quickly then goes out the remote control has been disabled Disabling all transmitters switches remote control 1 Press a...

Page 24: ...onnection of the output Status to interface with a wired automation system only When the shutter has finished opening or closing the Status output changes to 1 for 300 ms To lock GND Status 24V NO 15...

Page 25: ...rs see manual When you press open the shutters close Motors incorrectly connected Invert the connection of motors see manual The control knob connection is incorrect For Wired version Check the knob s...

Page 26: ...______________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________...

Page 27: ..._______________________ _____________________________________________________________________________ _____________________________________________________________________________ ____________________...

Page 28: ..._______________________ _____________________________________________________________________________ _____________________________________________________________________________ ____________________...

Reviews: