background image

 

 

 

 

The manufacturer or supplier shall not be liable for any damage resulting from the use of other 
products. If replacing the product, only use MANTION SMT or MANTION SMT-approved products. 

 

Radio control: 

 
Use of the wireless remote control is only authorized if any disturbance in the transmitter or 
receiver poses no danger to people or animals, or if such hazards are removed by other 
arrangements. 
The user of the wireless control is not protected against interference generated by other 
telecommunications installations and remote-controlled devices. If there is a high level of 
interference, contact the organization in charge of measuring wireless interference (radiolocation). 
Do not use the radio transmitter in places sensitive to radio transmissions (airports, hospitals) or 
only after taking all the necessary precautions. 
The swing shutter remote control may pose risks and for this reason please heed the following 
points when using it: 
 

1.  Make sure no object or person is within range of the swinging shutters. 
2.  Only operate them when direct visual inspection is possible. 

 

The wireless control is not a toy; do not let children play with it. Keep it out of reach of children and 
animals. 

 
Terms of the guarantee  

 
MANTION SMT products come with a 5 (five) years guarantee from the date of delivery. 
 
The guarantee is limited, as decided by MANTION SMT, either to replacement or to repair of 
products MANTION SMT recognizes as faulty, with the proviso that: 
 

1.  Subject to MANTION SMT's written permission to return the products, the said products are 

returned to MANTION SMT forthwith with the details of the fault and a copy of the 
installation engineer or dealer's bill stating the date of installation. 

 

2.  The products have been stored, installed, maintained and used in accordance with 

MANTION SMT's instructions and specifications. 

 
The guarantee is strictly limited to the provisions of this clause, and any other guarantee or 
liability, including loss of profits or damage directly or indirectly resulting from the sale or use of the 
products, is excluded. 
 
MANTION SMT shall on no account be liable for drilling and embedding conditions. 
 
MANTION SMT shall in any event only be liable for the WIBAT product. The guarantee does not 
apply in case of overvoltage or short-circuiting resulting for instance from connection errors, 
weather conditions such as lightning etc. The guarantee does not cover normal wear. 

 

 
 
 
 
 
 

Summary of Contents for SMT WIBAT

Page 1: ...1 INSTALLATION INSTRUCTION Product WIBAT VERSION EN 3 09 ANG 2 rue des M tiers 21110 Genlis T l 33 03 80 37 85 71 Fax 33 03 80 37 88 61 http www mantion smt fr...

Page 2: ...nd that of the power network where it will be used Do not connect the device without first checking that the control circuit is dead Check the installation frequently to detect any imbalances or signs...

Page 3: ...s not a toy do not let children play with it Keep it out of reach of children and animals Terms of the guarantee MANTION SMT products come with a 5 five years guarantee from the date of delivery The g...

Page 4: ...tation speed 1 9 rpm Opening or closing time limit 18 s Temperature to be used at 30 70 degrees C Colour Black other colours on request NB All of the data in the table is by way of indication dependin...

Page 5: ...1 5 mm 2 and 3 x 0 75 mm 2 1 Electrical box 60 mm depth hard wired version 1 concrete drill bit length according to wall thickness 1 Dispenser for chemical sealing 1 Sealing kit with mesh sleeves Mot...

Page 6: ...eding to the installation of the WIBAT When the hinges have been removed it is necessary to re block the holes left B CHOICE OF HINGES TO MECHANISE It is recommended to align stoppers with motorizatio...

Page 7: ...HINGES a Disassemble the shutters and mark the drilling site 20 mm from the edge of the strap hinge b Drill the strap hinges with a 6 5 mm drill bit right through and very perpendicular to the shutte...

Page 8: ...hinge of the shutter and draw in the area to be drilled with a pencil 4 DRILLING OF THE WALL A Remove the shutters Use the rotary comb hammer on drilling only position Do not use it on Hammer position...

Page 9: ...r sheathing Clean tidily the holes with a vacuum cleaner and a metallic brush The chemical seal doesn t adhere on dust 5 SETTING UP OF THE MECHANISED HINGE A Unscrew the two mounting screws 13 Take th...

Page 10: ...g WIBAT and the fitting box guard in the hole Make penetrate the sheath in the box guard In case the wall is porous and to avoid water seepage through the back of the product MANTION SMT recommended t...

Page 11: ...motor several times to twist the wires and get up again to the case E SHUTTERS INSTALLATION Position the rings 4 on the 2 hinges and readjust the shutters in place Fix the hinges motorized on the str...

Page 12: ...12 6 SEALING Pay attention to the correct vertical alignment of the hinges...

Page 13: ...the mesh sleeve then distribute 3 other blows while returning towards the wall Make this operation in the 4 holes envisaged to this end 5 Add the chemical seal around the fitting box in order to fill...

Page 14: ...acing silicone seal around the periphery of the protective flange 8 7 ASSEMBLY OF THE SHUTTER ON THE MECHANISED HINGES a Dismount the shutters b Withdraw the ring 4 c Mount back the shutters d Apply t...

Page 15: ...or the hard wired kit attach a 60 mm deep flush fitting box to the inside of the house and connect the wires as shown in the cabling diagram 2 Radio The casing can be installed at your liking in the f...

Page 16: ...s well as any obligations foreseen by the law and or by all obligations in force laid down for this purpose Electrical connection must take place without voltage Do not connect the sector before havin...

Page 17: ...17 ELECTRICAL CONNECTION HARD WIRED VERSION Wires for switch Feed not supplied Motor 1 Motor 2 230 V 24 VDC 2 x 1 5 2 x 0 75 Identification of motor 1 Motor 1 mechanises the covered flap...

Page 18: ...f motors Be careful to the polarity of the engines Following model If your WIBAT is intended for the mechanisation of a single flap shutter it is absolutely essential to connect it on motor 1 12 White...

Page 19: ...19 Feed connection Alimentation 24 V DC 10 24 V 230 V Connecting the power supply should meet the recommendations of the manufacturer thereof Feed not supplied Feed 24 V DC 10...

Page 20: ...ne of the two cavities located below the button Releasing the button the wire is then clamped in the cavity Check by gently pulling on it Reiterate handling for each of the three wires Radio switch co...

Page 21: ...close The Led blinks during all this cycle During the closing shutter 2 is shifted 6 secondes compared to shutter 1 When the shutter is close and the Led is no longer flashing the system is operation...

Page 22: ...ode 2 While the LED is on and not flashing press the open and close buttons simultaneously on the switch The LED flashes quickly then goes out the switch is now peered Peering a remote control 1 Press...

Page 23: ...ons simultaneously for the desired channel on the remote control The LED flashes quickly then goes out the remote control has been disabled Disabling all transmitters switches remote control 1 Press a...

Page 24: ...onnection of the output Status to interface with a wired automation system only When the shutter has finished opening or closing the Status output changes to 1 for 300 ms To lock GND Status 24V NO 15...

Page 25: ...rs see manual When you press open the shutters close Motors incorrectly connected Invert the connection of motors see manual The control knob connection is incorrect For Wired version Check the knob s...

Page 26: ...______________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________...

Page 27: ..._______________________ _____________________________________________________________________________ _____________________________________________________________________________ ____________________...

Page 28: ..._______________________ _____________________________________________________________________________ _____________________________________________________________________________ ____________________...

Reviews:

Related manuals for SMT WIBAT