background image

15.12.2014     

1

 

OPERATING INSTRUCTIONS 

MANKAR 

 

Models:  

MANKAR-ONE and MANKAR-TWO 

 

 

 

all types of the S- and Flex-models 

 

 
 

ULV- Applicator for weed control 

in areas of specialised cultivation such as nurseries, orchards and 

vineyards, ornamental plant and vegetable gardens, as well as 

agricultural, forestry, communal and non-cultivated lands. 

 
 

The unit has been developed for the undiluted 

application of ROUNDUP

 products (Glyphosate). 

 
 

Important: 

Before application, carefully read the usage instructions for the unit and the plant protective agent! 

Observe safety instructions! 

For questions regarding plant protective agents, consult the manufacturer! 

Observe the requirements and regional regulations for the use of herbicides and, if necessary, 

obtain approval from the responsible authorities (e.g. environmental conservation agency)! 

Application is to be performed only by a competent user. 

 
 

Remarks about usage of the unit: 

Settings:

 This system is not suitable for the application of water. 

Use herbicides for testing the spray action and calibration of the flow rate. 

Usage:

 Position the spray hood directly above the ground –  

if the spray hood is held too high, the danger of spray driftage exists. 

Cleaning:

 Do not clean the unit with a high-pressure spray or an intense water jet spray. 

 

 
 
 

Noise emission from the unit equates to less than 70 dB(A). 
 

Manufacturer: 

Mantis ULV-Sprühgeräte GmbH

 

Germany 21502 Geesthacht, Vierlander Str. 11 a

 

Tel49(0)4152-8459-0,   FAX +49(0)4152-8459-11 

Web: www.mantis-ulv.com   Email:  mantis@mantis-ulv.com 

 

Summary of Contents for MANKAR

Page 1: ...ents and regional regulations for the use of herbicides and if necessary obtain approval from the responsible authorities e g environmental conservation agency Application is to be performed only by a competent user Remarks about usage of the unit Settings This system is not suitable for the application of water Use herbicides for testing the spray action and calibration of the flow rate Usage Pos...

Page 2: ...miser or other small parts Keep pesticide applicators and chemical substances away from children Assembly and preparation for first use Unit assembly is described for the individual models Before using the unit for the first time charge the battery for at least 16 hours Attention Always follow the sequence 1 Insert the plug jack into the charger socket 2 Plug the charging unit into a 230 V mains s...

Page 3: ...re width of the spray hood The optimal spray width under standard operating conditions is set by the manufacturer In the event of deviations the screw F can be loosened in order to move the width adjustment on the atomiser see drawing Further details regarding operating width adjustment can be found on the pages for the individual applicator units Cleaning Do not clean the applicator unit with a h...

Page 4: ... M N O Checking the output volume 1 Place an underlay e g cardboard or paper on the ground and prop up the unit on stands 2 Fill the chemical tank with herbicide undiluted 3 Disconnect the hose from the spray hood and place a measuring cup underneath 4 Open the shut off valve initially setting the metering adjustment knob to the maximum flow rate and simultaneously turning the wheel wait until the...

Page 5: ...round and prop up the unit on stands 2 Fill the chemical tank with herbicide undiluted 3 Disconnect the hose from the spray hood and place a measuring cup underneath 4 Open the shut off valve initially setting the metering adjustment knob to the maximum flow rate and simultaneously turning the wheel wait until the chemical solution is evenly applied 5 Set the chemical solution volume according to ...

Page 6: ... 7 104170 Cable holder plastic Mankar Roll 8 100998 Countersunk Philips head screw M 4 x 12 mm VA 9 100992 Washer M8 Ø8 4 mm VA 10 101145 Allen head screw M 8 x 16 mm VA 11 104140 3 way ball valve Mankar Roll 12 104130 Flow controller mount Mankar Roll 13 104131 Flow controller clips Mankar Roll 14 103319 Flow controller cpl PC HQ PC glass 35 0 mm 15 104100 Frame pump carrier Mankar Roll 16 104150...

Page 7: ... Handle bar bushing Mankar Roll 10 104200 Handle bar guide Mankar Roll 11 104501 Fully suspended drive flange Mankar Roll 12 104502 Friction bearing left Mankar Roll 13 104100 Frame pump carrier Mankar Roll 14 104161 Pump protection ring Mankar Roll 15 104160 Pump protection Mankar Roll 16 104503 Friction bearing right Mankar Roll 17 103477 Wheel 530 x 60 mm pneumatic tyred Mankar Roll 18 104112 A...

Page 8: ... 8 104315 Spring retainer for pressure spring Mankar Roll 9 104314 Pressure spring rotary joint Mankar Roll 10 104316 Bolt Allen key 10 x 130 mm VA Mankar Roll 11 101145 Allen head screw M 8 x 16 mm VA 12 104701 Height adjustment ONE Mankar Roll 13 104731 Width adjustment ONE ONE S Mankar Roll 14 103826 Allen head screw M 6 x 45 mm VA 15 103467 Filister head screw M 6 x 12 mm VA with Allen head 16...

Page 9: ... Mount plastic power pack Mankar Roll ItemPart No Description ItemPart No Description 100527 Metering pump MANKAR 3 capacity 5 12 ml min for MANKAR 110 GP 100492 Metering pump MAFEX 3 capacity 2 20 ml min 1 100528 Pump housing for two channel pump Metering pump MANKAR 1 100493 Pump housing for single channel pump Metering pump MAFEX 2 102209 Rotor 3 chromed brass for piston pump MAFEX MANKAR 2 102...

Page 10: ...spray one sided Incorrect width setting Undo screws F see page 3 and adjust the width setting to the left or right Atomiser drips Metering valve incorrectly adjusted Check setting see table Atomiser disc faulty contaminated Replace clean disc Atomiser spray discharge contaminated Clean Atomiser foams Residual water in the system Completely empty tank hose and segmental atomiser Air in hose Hose co...

Page 11: ...eclare under our sole responsibility that the following products are in conformity with the provisions of the following Council Directive 2006 42 EG Typ MANKAR ONE MANKAR TWO Hiske Weissmann Managing Director Geesthacht January 2020 _______________________ _________________________________ Place and date of signature Name title and signature ...

Reviews: