15.12.2014
10
Troubleshooting
Fault
Cause
Rectification
Atomiser disc does
not rotate
Atomiser contaminated
Thoroughly clean atomiser, remove plant parts as
necessary
Battery empty
Charge battery
Fuse blown
Replace fuse on power pack
(Replacement fuses are located in the power pack
housing)
No electrical contact
Check cable and connector contacts
Battery faulty
Install new battery
Atomiser motor faulty
Install new motor
Connect the brown cable to Plus (+).
Atomiser spray
one-sided
Incorrect width setting
Undo screws (F, see page 3) and adjust the width setting
to the left or right
Atomiser drips
Metering valve incorrectly adjusted
Check setting, see table
Atomiser disc faulty/contaminated
Replace/clean disc
Atomiser spray discharge
contaminated
Clean
Atomiser foams
Residual water in the system
Completely empty tank, hose and segmental atomiser.
Air in hose
Hose connection not airtight
Shorten the hose slightly and fit it on the hose nipple.
Clamping bush fixing screw
Metering pump does not draw
Metering pump
Pump carrier
Metering pump does not draw
1. Loosen fixing screw
2. Pull metering pump out 1-2 mm
3. Tighten fixing screw