background image

 

ME697

 

   INTERFACE CARD

  (Eagle version) 

 

 

FLOWMETER (MES20) TO EAGLE COMPUTER   

PULSE  COUNTER  INTERFACE  CARD  

with manual batch facility and pulse fail safety. 

 

 

FEATURES: 

 

 

6x  8 digit LCD counters, displayed in millilitres. 

 

 

Supports up to six MES20 flowmeters. 

 

 

Optional variable pulse dividers. 

 

 

110 - 240vac pulse outputs (Triac switching)  

with LED indication.  

 

 

Provides important cross-reference batch figure. 

 

 

Pulse Fail and Batch Limit safety override  

with LED warning indicators and alarm. 

 

 

6 channel override batching facility. 

 

 

Easy plug-in connectors. 

 

 

Compact housing.

 

 

 

 

 

INTRODUCTION

 

The ME697 counter divider interface card was designed to act as a support product in interfacing upto six ManuFlo 
admixture 20mm pulse output flow meters  ( MES20, KGG20, MEK20 )  with Eagle and other USA industrial computer 
systems, requiring low frequency pulse rates and  110-240vac pulse inputs. This new design incorporates new high 
resolution missing pulse and maximum batch  limit overrides, as well as a six-channel manual batching facility. 
 

FUNCTION 

The computer system provides an AC output start and hold drive signal (black Opto22) to ME697 start input. The 
ME697 output drive supplies power to external contactor coils driving pumps and/or solenoids. ME697 supplies 
+12VDC to flowmeters which in turn send back pulses which are counted by individual channel LCD displays in 
millilitres. The pulses are then sent  to the computer inputs (yellow Opto22). When the computer system has OPTO22, 
110 - 240 vac input optos, incoming pulses are limited to 14 Hz maximum. Due to high resolution pulsing of 
flowmeters, the pulse rates must be divided. The onboard selectable dip switches are then set to the desired pulse 
division rate (see Fig.1).  
 
The divided output pulses are indicated by the pulse LEDs. The pulses are stepped up (via Motorola MOC3041 Triacs) 
to 110 - 240 vac switching pulses. These pulses arereceived by the computer input card (through Yellow OPTO22). 
When computer has completed batch cycle, a 110 or 240 vac reset signal is supplied to the ME697 master reset relay, 
thus reseting all counters.  
 

 

 

 

 

 

 

 

 

 

 

 

 

SAFETY OPERATION 

If, at any time during batch cycle, any flowmeter stops pulsing (e.g. due to flow obstruction, failure, blockage, pump 
failure etc), or the preset upper safety limit is reached, the inbuilt Pulse Fail feature will activate, shutting down flow 
regardless of computer's status operation. If Pulse Fail (P.F.) is activated, warning LED(s) will illuminate, indicating the 
channel at fault. Also, an audible alarm will sound. If upper batch limits are set, and if they are reached, the same 
safety features will activate. If channel(s) pulse failed, remember the quantity displayed. Reset unit to resume batching. 
 

Order Code for ME697 for Jonel Computer: ME697-1A-2A-3A-4A-5A (see Page 7)

 

Manu

Flo

 

 

®

 

 

 

Flow Measurement Products 

Page 1 

MANU ELECTRONICS

 

PTY LTD

 

 

Summary of Contents for ManuFlo ME697

Page 1: ...d by individual channel LCD displays in millilitres The pulses are then sent to the computer inputs yellow Opto22 When the computer system has OPTO22 110 240 vac input optos incoming pulses are limited to 14 Hz maximum Due to high resolution pulsing of flowmeters the pulse rates must be divided The onboard selectable dip switches are then set to the desired pulse division rate see Fig 1 The divide...

Page 2: ...ng on ME697 card from the computer supply Do not mix active pump drive with computer s Uninteruptable Power Supply UPS NOTE Neutral J2 and J5 is already bridged internally J5 active line after switch and fuse is bridged to J1 Active and J3 Active Only wire A N E J5 power input plug Six wires from J1 to computer yellow Opto22 pulses Seven wires from J2 to computer black Opto22 six start drives one ...

Page 3: ... 8 of Connector J2 If there is still a problem then it is a Computer issue that the master reset is stuck on Disconnect the plug connecting the Computer to J2 and batch manually if the batching computer s black Optos are leaky i e there is more than 60vac residual voltage after Opto latches off which could cause batching to continue because the ME697 relay is being held on then o replace the Black...

Page 4: ...s but may not be required if the installation has reasonable head height a 3 Way Valve to provide an easily accessible calibration point ADMIX STORAGE TANK PUMP Gate Valve restricts flow Filter Non Return Valve tank Valve Flowmeter Non Return Valve optional 3 Way Valve calibration point optional Solenoid to prevent Venturi effect if injecting into water lines outlet line above level of Storage Tan...

Page 5: ...ME697 Eagle version Page 5 A ...

Page 6: ...ME697 Eagle version Page 6 ...

Page 7: ...ER SUPPLY to card 1A 240 vac power supply 1B 110 vac power supply 1C 24 vac power supply 1D 24 VDC power supply START INPUT DRIVES and MASTER RESET from Computer starts 2A 240 vac power supply 2B 110 vac power supply 2C 24 vac power supply 2D 24 VDC power supply START OUTPUT DRIVES from ME697 to contactor coils and solenoids 3A 240 vac power supply 3B 110 vac power supply 3C 24 vac power supply 3D...

Reviews: