25
D00619EN
-
v0
SWING OPERATOR
-
INSTALLATION MANUAL
5.14 Connector to Auxiliary Outputs
SIGNAL
DEFAULT
*
DESCRIPTION
FUNCTION
AUX OUT 1
AUX OUT 2
NA
A signal that, depending on its setting, can have the following configurations:
0
-
Sensors supervision
Signal to manage the supervised sensors.
1
-
Interlocking
Allows the configuration of the device output, to enable
interlocking between the two operators.
2
-
Open
-
door state
Output that signals the open
-
door state.
3
-
Closed
-
door state
Output that signals the closed
-
door state.
4
-
Malfunction
Output that signals the operator malfunction state.
5
-
Lock control repetition
This is a repetition of the signal that arrives from the lock
control.
AUX IN 1
AUX IN 2
NO
7
-
Stand
-
by state
When the contact is closed, the door enters stand
-
by mode (unlocked
and deactivated). This logic setting only operates with the door in the
closed position.
8
-
Activate again from
Stand
-
by
When the contact is closed, the door activates again after being in
stand
-
by.
9
-
Step by Step function
For each impulse, the door, if closed, performs an opening manoeu-
vre, or if open, performs a closing manoeuvre.
10
-
Fire alarm
VectorS: When the contact is closed, all commands are deactivated
and the door is closed by the spring
11
-
Manual operation
VectorS: When the contact is closed, the door enters manual opera-
tion and the logic settings switch (Fig.1B) is excluded
12
-
Door closed
VectorM: When the contact is closed, the door is placed in door
-
closed mode and the logic settings switch (Fig.1B) is excluded
NO = Normally Open
NC = Normally Closed
All inputs must refer to the common (COM); those indicated are preset configurations (default). These can be modified (see
section 5.17
Display Management
)
NO =Normally Open
NC =Normally Closed
All inputs must refer to the common (COM); those indicated are preset configurations (default). These can be modified (see
section
5.17 Display Management
)
WARNING: To connect the auxiliary output signals, see the electrical connections shown in Fig. 23.
Maximum contact load: 24V
-
100mA
WARNING: Overloading the card capacity may damage it.
Fig. 23.
5.14
A
L
O
C
K
G
N
D
D
A
T
A
PW
F
R
S
T
O
U
T
15
VD
C
C
O
M
A
U
X
-
I
N
2
A
U
X
-
I
N
1
S
T
A
R
T
2
S
T
A
R
T
1
C
O
M
K
EY
SA
F
E
-
C
L
O
SE
SA
F
E
-
O
P
EN
C
O
M
A
U
X
–
O
U
T
2
A
U
X
–
O
U
T
1
A
B
A
B
+
-
-
+
Summary of Contents for VECTOR
Page 1: ...Installation Manual VECTOR Operator ...
Page 15: ...14 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 4 A 5 4 B Fig 4 Fig 5 D A B E C F ...
Page 16: ...15 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 4 C 5 4 D Fig 6 Fig 7 A A A A ...
Page 19: ...18 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 5 A 5 5 B Fig 12 Fig 13 A A ...
Page 47: ...46 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL CARACTERÍSTICAS MECÁNICAS 10 4 Notes ...