EasyBuilder Pro Software Settings 

Launch EasyBuilder Pro software, select your project file, press F7 shortcut key to open the download 
dialog box: Select Ethernet > IP tab > Enter your HMI IP > Click Download to download this project   
file to HMI.   
Using screensaver and backlight saver is recommended in order to avoid image persistence caused 
by displaying the same image on HMI for a long time. 
( Please refer to EasyBuilder Pro User Manual for software operation details. ) 

Communication Connections 

 

Con.B

Con.A 

COM1

/

COM3 [RS232] 9 Pin, Male, D-sub 

  COM2

/

COM3 [RS485]/CAN Bus 9 Pin, Female, D-sub

 

Touchscreen Calibration & Restore Factory Default 

Touchscreen Calibration: 

Press and hold anywhere on the screen when HMI starts until it enters touchscreen calibration mode. 

Restore Factory Default: 

Follow Step 5 to open the Setting dialog box. Go to "Reset options" tab, press the button of 

“Reset HMI 

to default

”. An Attention window shows, enter “yes”. 

Another way to restore factory default is entering 

“default111111” when logging in. An Attention window 

shows, enter 

“yes”. 

Please note that the projects and data stored in the unit are all cleared after restoring factory default. 

Battery Replacement 

Battery replacement shall be performed by qualified personnel only and care must be taken when 
handling lithium batteries.

NOTE: 

Make  sure  that  all  local  and  national  electrical  standards  are  met  when 

installing the unit. Contact your local authorities to determine which codes apply.

 

Power

 

Use power output that meets SELV (Safety Extra-Low Voltage) requirements. The unit can be 
powered  by  DC  power  only,  voltage  range:  24

±

20%,  compatible  with  most  controller  DC 

systems. The power conditioning circuitry inside the unit is accomplished by a switching power 
supply. The peak starting current can be as high as 2A. 

 

Fusing Require- 
ments 

If the display does not come on within 5 seconds of power up, remove power. A resettable fuse 
will protect against overcurrent faults in DC circuit and the resetting will take place after a period 
of time. Check wiring for proper connections and try to power up again. 

High Voltage

 

A  resettable  fuse  will  prevent  damage  for  overcurrent 

condition  however  it  isn’t  guaranteed. 

DC voltage sources should provide proper isolation from main AC power and similar hazards. 

Emergency Stop

 

A Hard-wired EMERGENCY STOP should be fitted in any system using an HMI to comply with 
ICS Safety Recommendations. 

 

Supply Voltage 
Condition

 

Do not power the unit and inductive DC loads, or input circuitry to the controller, with the same 
power supply. Note: The 24 VDC output from some controllers may not have enough current to 
power the unit.

Wire Routing

 

a.

Power wire length should be minimized (Max: 500m shielded, 300m unshielded).

b.

Please use twisted pair cables for power wire and signal wire and conform to the 
impedance matching.

c.  If wiring is to be exposed to lightning or surges, use appropriate surge suppression 

devices.

d.

Keep AC, high energy, and rapidly switching DC power wiring separated from signal wires.

e.

Add a resistor and capacitor in the parallel connection between the ungrounded DC power
supply and the frame ground. This provides a path for static and high frequency 
dissipation. Typical values to use are 1M Ohm and 4700pF.

 

Hardware 
Considerations

 

The  system  designer  should  be  aware  that  devices  in  Controller  systems  could  fail  and 
thereby  create  an  unsafe  condition.  Furthermore,  electrical  interference  in  an  operator 
interface  can  lead  to  equipment  start-up,  which  could  result  in  property  damage  and/or 
physical injury to the operator. 
If  you  use  any  programmable  control  systems  that  require  an  operator,  be  aware  that  this 
potential safety hazard exists and take appropriate precautions. Although the specific design 
steps  depend  on  your  particular  application,  the  following  precautions  generally  apply  to 
installation  of  solid-state  programmable  control  devices,  and  conform  to  the  guidelines  for 
installation of Controllers recommended in NEMA ICS 3-304 Control Standards.

 

 

Programming 
Considerations

 

To  conform  to  ICS  Safety  Recommendations,  checks  should  be  placed  in  the  controller  to 
ensure  that  all  writable  registers  that  control  critical  parts  of  plant  or  machinery  have  limit 
checks built into the program, with an out-of-limit safe shut down procedure to ensure safety of 
personnel. 

1010-1086_rev00

_191127

 

DANGER 

CAUTION 

Limited Warranty 

PIN# 

COM1 

[RS232]4W 

COM3 

[RS232]2W 


RxD 

TxD 


GND 


RTS 

TxD 

CTS 

RxD 

 

PIN# 

COM2 

[RS485]2W 

COM2 

[RS485]4W 

COM3 

[RS485]2W 

CAN 

Bus 

Data- 

Rx- 

Data+ 

Rx+ 

Tx- 

Tx+ 

GND 

Data- 

CAN_L 

CAN_H 

Data+ 

NOTE: 
1.

Only Tx & Rx (no RTS/CTS) may be used for COM1 RS232 when COM3 RS-232 is also used.

2.

COM2 / COM3 RS-485 2W Supports MPI 187.5K, please use one at a time.

3.

To communicate properly, the CAN Bus has to be 

terminated at both ends by two 120Ω terminal 

resistances.

CAUTION

NN

NOTE: 

Make sure that all local and national electrical standards are met when installing 
the unit. Contact your local authorities to determine which codes apply. 

CAUTION

NN

NOTE:   

Make sure that all local and national electrical standards are met when installing 
the unit. Contact your local authorities to determine which codes apply. 

A copy of the Warranty and Limitation of Liability is contained in the product box. It can 

also be found on the Maple Systems website.