background image

 

Installation and Startup Guide

This document covers the installation of cMT3102X Series HMI, for the detailed specifications and 

operation, please refer to Datasheet, Brochure and EasyBuilder Pro User Manual. Please read all 

warnings, precautions, and instructions on the device carefully before use. 

Install Environment: 

NEMA Rating

 

The HMI product is NEMA 4 rated, indoor use only.

 

Electrical 

Environment

 

The 

HMI product has been tested to conform to European CE requirements. This 

means that the circuitry is designed to resist the effects of electrical noise. This 

does not guarantee noise immunity in severe cases. Proper wire routing and 

grounding will insure proper operation.

 

Environmental 

Considerations

 

(1) Make sure that the displays are installed correctly and that the operating

limits are followed. Avoid installing units in environments where severe

mechanical vibration or shocks are present.

(2) Do not operate the unit in areas subject to explosion hazards due to

flammable gases, vapors or dusts.

(3) Do not install the unit where acid gas, such as SO2 exists.

(4) This device should be mounted in the vertical position and for use on the flat

surface enclosure.

(5) Conform to UL 61010-1 and UL 61010-2-201 safety requirement for use in

Pollution Degree 2 Environment and dry location.

(6) Relative Humidity: 10% ~ 90% (non-condensing)

Cleaning 

Considerations 

Clean the device using dry cloths. Do not use liquid or spray detergents for 

cleaning. 

IP Rating 

IP 66 

Warning 

Protection impairment if used in a manner not specified by the manufacturer. 

Déficit de protection si utilisé d'une manière non spécifiée par le fabricant. 

Unpacking the Unit

Unpack and check the delivery. If damage is found, please contact the supplier.

 

 

NOTE: 

Place the operator panel on a stable surface during installation. Dropping it or letting it 

fall may cause damage. 

The package includes: 

(1) Installation Instruction, 2-sided A4 *1 (2) Human Machine Interface *1 (3) Power Connector *1

(4) Brackets & Screws *1 pack (5) USB Stick Clamp & Tying Strap *1

Installation Instructions

Use a control box that provides enough stiffness. Cutout 

Dimension: 260 mm x 202 mm. Secure the operator panel in 

position, using all the fastening holes and the provided 

brackets and screws. Screw Torque: 2.6 ~ 3.9 lbf.in. (For 

reaching waterproof effect and preventing the panel from 

being deformed.) 

Plan for adequate space around the unit and inside the 

enclosure, for ventilation and cables. Consider the heat from 

other devices inside the enclosure. The ambient temperature around the unit must be 0 ~ 50°C 

Minimum required clearances (along the overlay): Top 15 mm / Bottom 50 mm / Sides 80 mm 

Maximum panel thickness: 4.5 mm 

USB Stick Clamp Usage 

Combining the USB Stick with the clamp and the tying strap can prevent USB stick from disconnecting 

with HMI when strong vibration is present. 

1. Insert the USB connector to the clamp and tie them together with the tying strap.

2. Press the spring and insert the USB stick into HMI.

Expansion Module and Magnetic Mount Antenna 

1. Connect the expansion module by inserting it into the given slot in HMI’s rear cover.

2. Tighten the module to HMI’s rear cover using two M3*8L screws.

3. Lock the antenna’s SMA connector to the module’s connector.

Please reserve space for installing the antenna with minimum bend radius taken into consideration, in

order to prevent physical damage to the antenna or impairment of the antenna’s performance.

Power Connections 

Power Connector Specifications:   

Wire AWG: 24~12 

Wiring Conductor Minimum Temperature: 75°C 

Screw Torque: 4.5 lbf-in (max.) 

Copper conduct only.

 

Spécifications du connecteur d'alimentation: 

AWG de fil: 24 ~ 12 

Température minimale du conducteur de câblage: 75°C 

Couple de vis: 4.5 lbf-in (max.) 

Conducteur en cuivre seulement

NOTE: 

1. Connect 

positive DC line to the ‘+’ terminal and the DC ground to the

‘-’ terminal.
2. When downloading project using a USB cable, do not connect HMI
with PLC and PC simultaneously, for electric potential difference may 
result in damage to HMI or PC.