Name

 

Recommended

 

Settings

 

Options

 

Important Notes

 

Settings: Timeout 
(sec) 

1.0 

0.1 to 25.5 

Adjust if longer timeout is 
required. 

Settings: Turn around 
delay (ms): 

0-1000 

Timeout period between HMI 
polls. 

Settings: Send Ack 
Delay : 

30 

 

 

Settings: Reserved 1: 

 

Not Applicable 

Settings: Reserved 2: 

 

Not Applicable 

Settings: Reserved 3:  0 

 

Not Applicable 

Interval of block pack 
(words): 

0-512 

 

Max. read-command 
size (words): 

16 

 

Not Adjustable 

Max. write-command 
size (words): 

 

Not Adjustable 

 

Summary of Contents for Graphic HMIs

Page 1: ... Please refer to the Installation and Operations Manual for information on connecting multiple Graphic HMIs to a single PLC port Communications Cable The Graphic HMI should be connected to the controller s PPI port A list of communications cables offered by Maple Systems as well as cable assembly instructions to assist you in assembling your own communications cable are available on our website at...

Page 2: ...ddddd V Memory SMW 0 1534 dddd Special Memory T 0 255 ddd Timer C 0 255 ddd Counter AIW 0 110 ddd Analog Input AQW 0 110 ddd Analog Output VD 0 20476 ddddd V Memory Double Word Discrete Memory The following table lists the PLC s discrete memory ranges that the Graphic HMIs are able to access Please note that your PLC s memory range may be smaller or larger than that supported by these HMIs The fol...

Page 3: ...tant Notes Name Siemens S7 200 Smart PPI Description label HMIor PLC PLC Location Local Local Remote Select Local if PLC directly connected to HMI Remote if PLC connected thru another HMI PLC type Siemens S7 200 Smart PPI PLC I F RS485 2W RS 232 RS 485 2W RS 485 4W Must match the controller port setting PLC default station no 2 1 126 Must match the node address assigned to the PLC Setting COM COM1...

Page 4: ... sec 1 0 0 1 to 25 5 Adjust if longer timeout is required Settings Turn around delay ms 5 0 1000 Timeout period between HMI polls Settings Send Ack Delay 30 Settings Reserved 1 0 Not Applicable Settings Reserved 2 0 Not Applicable Settings Reserved 3 0 Not Applicable Interval of block pack words 5 0 512 Max read command size words 16 Not Adjustable Max write command size words 2 Not Adjustable ...

Reviews: