background image

2

OIT3185A/4185A

1010-0104, REV 03

COPYRIGHT NOTICE

This manual is a publication of Maple Systems, Inc., and is provided for use by its customers only. The

contents of the manual are copyrighted by Maple Systems, Inc.; reproduction in whole or in part, for use

other than in support of Maple Systems equipment, is prohibited without the specific written permission

of Maple Systems.

WARRANTY

Maple Systems warrants each product to be free from electrical and mechanical defects in materials and

workmanship for a period of two years from the date of shipment. This warranty does not apply to

defects in the Products caused by abuse, misuse, accident, casualty, alteration, negligence, repair not

authorized by Maple Systems, use on current or voltages other than specified by Maple Systems, or

application or installation not in accordance with published instruction manuals. This warranty is in lieu

of any other warranty either expressed or implied.
Maple Systems’ liability is limited to the repair or replacement of the Product only, and not costs of

installation, removal, or damage to user’s property or other liabilities. If Maple Systems is unable to

repair or replace a nonconforming Product, it may offer a refund of the amount paid to Maple Systems

for such Product in full satisfaction of its warranty obligation. Maximum liability of Maple Systems is

the cost of the Product.
Information furnished by Maple Systems, Inc., is believed to be accurate and reliable. However, no

responsibility is assumed by Maple Systems for the use of this information nor for any infringements of

patents or other rights of third parties which may result from its use. No license is granted by

implication, or otherwise, under any patent or patent rights of Maple Systems, Inc. Maple Systems

retains the right to revise or change its products and documentation at any time without notice.

IF SERVICE IS REQUIRED

Package the unit in its original packaging container or, if unavailable, any suitable rigid container. If a

substitute container is used, surround the unit with shock absorbing material; damage in shipment is not

covered by the warranty. Include a letter with the unit describing the difficulty and designating a contact

person. Send to the following address: Maple Systems, Inc., 808 134th Street SW, Suite120, Everett,

WA 98204.
Only Products that have been issued a Return Material Authorization (RMA) number from Maple

Systems may be returned. All RMAs must be accompanied with a written purchase order for tracking

purposes or, in the case of out-of-warranty repairs, for repair charges on a time and material basis.
All returns will be tested to verify customer claims of noncompliance with the product warranty.

Improper return packaging which makes verification impossible will void the warranty. Products

passing the tests will be returned “AS IS” to the customer.
If noncompliance is verified and is not due to customer abuse or the other exceptions described with

product warranty, Maple Systems will, at its option, repair or replace the Product returned to it, freight

prepaid, which fail to comply with the foregoing warranty, provided Maple Systems is notified of such

noncompliance within the one-year warranty period.

APPLICATIONS ASSISTANCE

This manual is designed to provide the necessary information for trouble-free installation and operation

of your new Operator Interface Terminal (OIT). However, if you need assistance, please call Maple

Systems at 425-745-3229 or visit our web site at www.maple-systems.com.

Appendix C

Dimensional Outline

INSTALLATION MANUAL

23

1010-0104, REV 03

Summary of Contents for OIT3185

Page 1: ...Connect mounting stud s to control panel earth ground 808 134th Street SW Suite 120 Everett WA 98204 USA 425 745 3229 Fax 425 745 3429 E mail maple maple systems com URL www maple systems com CLEAR ENTER 9 8 7 Help 6 5 Alarm Ack 4 Next Msg Del Last Msg Page Down 0 3 2 1 Toggle F8 F2 F9 F3 F10 F4 F5 F6 F7 F1 CLEAR ENTER 9 8 7 Help 6 5 Alarm Ack 4 Next Msg Del Last Msg Page Down 0 3 2 1 Toggle F8 F2...

Page 2: ...or otherwise under any patent or patent rights of Maple Systems Inc Maple Systems retains the right to revise or change its products and documentation at any time without notice IF SERVICE IS REQUIRED Package the unit in its original packaging container or if unavailable any suitable rigid container If a substitute container is used surround the unit with shock absorbing material damage in shipmen...

Page 3: ...an installation feeding the manufacturing or similar plant The product described in this document is intended for use solely in an industrial environment as defined above When installed in Europe any other application is in contravention of European Union Directives and a breach of those laws 1010 0104 REV 03 22 OIT3185A 4185A INSTALLATION MANUAL 3 1010 0104 REV 03 Read Me First Your new Maple Sys...

Page 4: ... equipment needs to be stored returned to Maple Systems or transported for any reason Appendix A OIT Hardware Specifications Mechanical Material Aluminum sealed to NEMA 4 12 when panel mounted Mounting Panel Wiring Unit is field wired by user to external power plug and shielded RJ 45 communications connectors Weight 1 pound 0 45 kg OIT3185A Environmental Operating Temp 14 to 149 F 10 to 65 C Stora...

Page 5: ...cs against the edge of the access slot in the aluminum plate A paper shoehorn may be used to prevent this Gasket Aluminum Plate Front of OIT Figure 11 Custom Keypad Legend Installation INSTALLATION MANUAL 5 1010 0104 REV 03 Table of Contents 1 Safety Warnings 6 1 1 Hazardous Locations 6 2 Control Panel Design Guidelines 7 2 1 Control Panel Grounding 7 2 2 Power Supply Selection 8 2 3 OIT Cable Rou...

Page 6: ...imate enclosure must be in accordance with Class I Division 2 wiring methods as described in the National Electrical Code ANSI NFPA 70 All peripheral equipment must be suitable for the location in which it is used Use only a Class 2 power source as described in the National Electrical Code ANSI NFPA 70 WARNING Use only with Class 2 power source limited to 30 VDC open circuit and 8A short circuit 1...

Page 7: ...er installation Pay careful attention to the placement of system components and associated cable routing These items can significantly enhance the performance and integrity of your control application 2 1 Control Panel Grounding The control panel should be connected to a good high integrity earth ground both for safety considerations and shielding purposes This must be a reliable earth ground with...

Page 8: ... differential mode attenuation The power supply that provides power to the OIT should not be used to power switchingrelaysorsolenoidsunlessnoisefiltercapsareconnectedtoeachrelay 2 3 OIT Cable Routing Input and output I O wiring must be in accordance with Class I Division 2 wiring methods and in accordance with the authority having jurisdiction Always route the OIT communication cable and power cab...

Page 9: ...ted When photocopying Use only non glossy stock which is 0 004 0 008 inches 0 1 0 2 mm thick Check photocopy accuracy with the printed check dimension When illustrating Use the tick marks to locate the switch centers Refer to the computer generated legend dimensions if unsure NOTE Pressing the center of the switch is critical for switch actuation Recommended key size is 0 500 inches 12 7 mm square...

Page 10: ... with the printed check dimension The panel cutout should be cleaned and deburred before the OIT is installed 3 3 Enclosures Allow enough spacing within an enclosure for adequate ventilation For some applications you may have to consider heat produced by other devices within a panel The ambient temperature around the terminal must be maintained as specified 10 OIT3185A 4185A 1010 0104 REV 03 4 OIT...

Page 11: ...S 4 RETURN 5 TXD 6 RXD 7 RXD 8 RXD Figure 6 Port 1 Pin Outs 3 4 Mount OIT to Panel STEPS 1 Gently position the OIT with the studs through the panel mounting holes 2 Secure the OIT by installing the four 6 32UNC mounting nuts using a 5 16 inch socket wrench or nut driver CAUTION Do not torque the 4 mounting nuts to over 15 pound inches Over torquing can strip the threads or pull the studs loose RE ...

Page 12: ...PLY OIT Red Output Black Output Shield Wire Case Ground Shield NOTE The power connector on the OIT has M3 slotted screws 3 6 Connect OIT to PLC Host Each PLC host supported by Maple Systems has its own wiring requirements Maple Systems offers pre constructed OIT to PLC communication cables for most PLCs Most cables are available for same day shipment from Maple Systems They are built and tested fo...