background image

4

OIT3185A/4185A

1010-0104, REV 03

Introduction

Thank you for purchasing a Maple Systems OIT3185 or OIT4185. You have

selected a rugged, reliable, and powerful operator interface for your application.

This booklet describes the steps necessary to ensure trouble-free OIT system

operation.

Please read this booklet carefully!!

Static Awareness

It is best NOT to remove the rear cover on the OIT. When the rear cover is removed

the circuitry inside is exposed to possible damage by electrostatic discharge during

handling. Minimize the possibility of electrostatic discharge by:
• Discharging personal static by grounding yourself prior to handling the OIT.
• Handling the OIT at static-free, grounded work station.
• Connecting the chassis of the OIT to a clean ground.
• Placing the OIT into an anti-static bag during transport.

Unpacking the Unit

Carefully unpack the OIT. Please read any instructions or cautions that appear on

the shipping container. Check all material in the container against the enclosed

packing list. Maple Systems, Inc., will not accept responsibility for shortages

against the packing list unless notified within 30 days. The equipment and its

accessories were inspected and tested by Maple Systems before shipment; all of the

equipment should be in good working order. Examine the equipment carefully; if

any shipping damage is evident, notify the carrier immediately. You are

responsible for claim negotiations with the carrier. Save the shipping container and

packing material in case the equipment needs to be stored, returned to Maple

Systems, or transported for any reason.

Appendix A

OIT Hardware Specifications

Mechanical

Material: Aluminum sealed to NEMA 4/12 when panel mounted
Mounting: Panel
Wiring: Unit is field-wired by user to external power plug and shielded RJ-45 communications connectors
Weight: 1 pound (0.45 kg)

OIT3185A Environmental

Operating Temp: +14 to +149°F (-10 to +65°C)
Storage Temp: -22 to +176°F (-30 to +80°C)

OIT4185A Environmental

Operating Temp: +14 to +149°F (-10 to +65°C)
Storage Temp: -40 to +185°F (-40 to +85°C)

Electric Noise Immunity

Emissions:

EN55011 (Group 1, Class B)—Generic commercial, light, and heavy industrial environments

EN50081-1—Generic domestic and light industrial environments

EN50081-2—Generic heavy industrial environment

Immunity:

EN50082-1—Generic domestic and light industrial environments

EN50082-2—Generic heavy industrial environment

Power Requirements

Input Voltage: +12 to +30 VDC, Class 2
Power Usage: 2.5 watts typical, 3 watts maximum

Display

OIT3185 Display Type: Backlit Liquid Crystal Display (LCD)—5 x 7 dot matrix with cursor
OIT4185 Display Type: Vacuum Fluorescent Display (VFD)—5 x 7 dot matrix with cursor
Display Character Size: 4 lines of 20 characters, 0.16 inches (4.1 mm) high
Display Viewing Angle: Approximately 90 degrees

Keypad

Key Type: Membrane switch with custom legending (all keys)
Feedback: Audible
Layout: 24 user-definable keys arranged in 3 rows
Operational Life: Three million operations

Communications

Serial Port: RS-232, RS-422, or RS-485
Baud Rates: 300, 600, 1200, 2400, 4800, 9600, or 19.2k

Internal Features

Memory: 128K x 8 Flash PROM for firmware protocol and configuration data—no battery required

INSTALLATION MANUAL

21

1010-0104, REV 03

Summary of Contents for OIT3185

Page 1: ...Connect mounting stud s to control panel earth ground 808 134th Street SW Suite 120 Everett WA 98204 USA 425 745 3229 Fax 425 745 3429 E mail maple maple systems com URL www maple systems com CLEAR ENTER 9 8 7 Help 6 5 Alarm Ack 4 Next Msg Del Last Msg Page Down 0 3 2 1 Toggle F8 F2 F9 F3 F10 F4 F5 F6 F7 F1 CLEAR ENTER 9 8 7 Help 6 5 Alarm Ack 4 Next Msg Del Last Msg Page Down 0 3 2 1 Toggle F8 F2...

Page 2: ...or otherwise under any patent or patent rights of Maple Systems Inc Maple Systems retains the right to revise or change its products and documentation at any time without notice IF SERVICE IS REQUIRED Package the unit in its original packaging container or if unavailable any suitable rigid container If a substitute container is used surround the unit with shock absorbing material damage in shipmen...

Page 3: ...an installation feeding the manufacturing or similar plant The product described in this document is intended for use solely in an industrial environment as defined above When installed in Europe any other application is in contravention of European Union Directives and a breach of those laws 1010 0104 REV 03 22 OIT3185A 4185A INSTALLATION MANUAL 3 1010 0104 REV 03 Read Me First Your new Maple Sys...

Page 4: ... equipment needs to be stored returned to Maple Systems or transported for any reason Appendix A OIT Hardware Specifications Mechanical Material Aluminum sealed to NEMA 4 12 when panel mounted Mounting Panel Wiring Unit is field wired by user to external power plug and shielded RJ 45 communications connectors Weight 1 pound 0 45 kg OIT3185A Environmental Operating Temp 14 to 149 F 10 to 65 C Stora...

Page 5: ...cs against the edge of the access slot in the aluminum plate A paper shoehorn may be used to prevent this Gasket Aluminum Plate Front of OIT Figure 11 Custom Keypad Legend Installation INSTALLATION MANUAL 5 1010 0104 REV 03 Table of Contents 1 Safety Warnings 6 1 1 Hazardous Locations 6 2 Control Panel Design Guidelines 7 2 1 Control Panel Grounding 7 2 2 Power Supply Selection 8 2 3 OIT Cable Rou...

Page 6: ...imate enclosure must be in accordance with Class I Division 2 wiring methods as described in the National Electrical Code ANSI NFPA 70 All peripheral equipment must be suitable for the location in which it is used Use only a Class 2 power source as described in the National Electrical Code ANSI NFPA 70 WARNING Use only with Class 2 power source limited to 30 VDC open circuit and 8A short circuit 1...

Page 7: ...er installation Pay careful attention to the placement of system components and associated cable routing These items can significantly enhance the performance and integrity of your control application 2 1 Control Panel Grounding The control panel should be connected to a good high integrity earth ground both for safety considerations and shielding purposes This must be a reliable earth ground with...

Page 8: ... differential mode attenuation The power supply that provides power to the OIT should not be used to power switchingrelaysorsolenoidsunlessnoisefiltercapsareconnectedtoeachrelay 2 3 OIT Cable Routing Input and output I O wiring must be in accordance with Class I Division 2 wiring methods and in accordance with the authority having jurisdiction Always route the OIT communication cable and power cab...

Page 9: ...ted When photocopying Use only non glossy stock which is 0 004 0 008 inches 0 1 0 2 mm thick Check photocopy accuracy with the printed check dimension When illustrating Use the tick marks to locate the switch centers Refer to the computer generated legend dimensions if unsure NOTE Pressing the center of the switch is critical for switch actuation Recommended key size is 0 500 inches 12 7 mm square...

Page 10: ... with the printed check dimension The panel cutout should be cleaned and deburred before the OIT is installed 3 3 Enclosures Allow enough spacing within an enclosure for adequate ventilation For some applications you may have to consider heat produced by other devices within a panel The ambient temperature around the terminal must be maintained as specified 10 OIT3185A 4185A 1010 0104 REV 03 4 OIT...

Page 11: ...S 4 RETURN 5 TXD 6 RXD 7 RXD 8 RXD Figure 6 Port 1 Pin Outs 3 4 Mount OIT to Panel STEPS 1 Gently position the OIT with the studs through the panel mounting holes 2 Secure the OIT by installing the four 6 32UNC mounting nuts using a 5 16 inch socket wrench or nut driver CAUTION Do not torque the 4 mounting nuts to over 15 pound inches Over torquing can strip the threads or pull the studs loose RE ...

Page 12: ...PLY OIT Red Output Black Output Shield Wire Case Ground Shield NOTE The power connector on the OIT has M3 slotted screws 3 6 Connect OIT to PLC Host Each PLC host supported by Maple Systems has its own wiring requirements Maple Systems offers pre constructed OIT to PLC communication cables for most PLCs Most cables are available for same day shipment from Maple Systems They are built and tested fo...