background image

Appendix B

Building Your Own Power Cable

When building your own power cable, slide the two ferrite shield beads that were included in the

connector kit from Maple Systems onto the cable shield wire before inserting the wire into Pin 3 of

the power connector. These ferrite shield beads are required for CE compliance and noise immunity.

24

OIT3200/3250

1010-0081A, REV 04

Wire Color

3

2

1

SHIELD

BLACK

RED

WIRE LIST

Pin #

Shield

.30"

1.50"

0.5"

BLK

SHIELD

3

RED

2

1

Power Connector

3

1

2

Signal

Chassis Ground

Signal Ground

+12V to 30VDC

OIT

Push stripped wire into ROUND
holes while holding clamps
open with a screwdriver.

Push screwdriver into

RECTANGULAR holes

to open wire clamps.

(Note: There is an optional set

of holes on the bottom side.)

CONNECTOR is a three-position

power connector (supplied with the OIT).

18AWG Shielded (RED/BLACK)
Recommended

[7.6]

[38.1]

[12.7]

3/8" Heatshrink, 2.0" Long

Shield

0.30"

[7.6]

2.00"

[50.8]

(Covers ferrite beads)

2 Ferrite beads

(supplied with the OIT)

Figure 19 Power Connector Pin-Out

Summary of Contents for OIT3200

Page 1: ...LARM DOWN MESSAGE PAGE UP NEXT LAST MESSAGE TOGGLE HELP SETUP DELETE CLEAR E N T E R F1 F5 F9 F2 F6 F10 F3 F7 F11 F4 F8 F12 2 3 4 6 5 7 8 MESSAGE ALARM RUN PRINT 1 0 7 4 8 5 1 2 9 6 3 PAGE ACK ALARM D...

Page 2: ...icense is granted by implication or otherwise under any patent or patent rights of Maple Systems Inc Maple Systems retains the right to revise or change its products and documentation at any time with...

Page 3: ...0 When power is first applied the OIT s display will indicate that it needs to be configured Use the OITware 200 or STEPware 100 software to create a file or project that can be downloaded to the OIT...

Page 4: ...to handling the OIT Handling the OIT at static free grounded work stations Connecting the chassis of the OIT to a clean ground Placing the OIT into an anti static bag during transport Unpacking the U...

Page 5: ...t OIT to Power 11 2 6 Connect OIT to PLC Host 12 3 OIT Configuration Wiring 13 3 1 Connect OIT3200 to PC for Configuration 13 3 2 Connect OIT3250 to PC for Configuration 14 4 OIT3250 Special Features...

Page 6: ...d from the hinged control panel to the rest of the enclosure 1 2 Power Supply Selection The power supply used to power the OIT should have an output between 12 and 30 VDC The voltage should measure be...

Page 7: ...inches 20 cm of separation between the OIT cables and other power wiring If voltages greater than 120 VAC are used in the system greater separation is required If theOIT cables must come near ACwiring...

Page 8: ...wer two pins of a 3 pin header This is called Position A 3 Move the jumper to the upper two pins of the 3 pin header Position B Ensure that the jumper is pressed fully into place 4 Replace the rear co...

Page 9: ...o Panel INSTALLATION MANUAL 9 1010 0081A REV 04 This area to be free of paint 5 15 0 01 130 8mm 0 3 Corner drill permissable 4 70 0 03 6 00 0 01 152 4mm 0 3 8 00 0 03 1 00 ref 25 4mm 0 23 ref on REAR...

Page 10: ...Panel The green ground wire assembly supplied with the OIT must be installed as shown This provides a good earth ground connection to the OIT s bezel and rear cover If your control panel is metal be s...

Page 11: ...to the OIT power supply 3 The power cable should not be any longer than necessary If needed a cut the power supply cable to the appropriate length b strip the cable shield back on the power cable c s...

Page 12: ...ide or the STEP1 Protocol Operation Manual forinformation onconstructing OIT to ASCII host communication cables STEPS 1 Connect the DE9P plug end of the communication cable to Port 1 on the OIT which...

Page 13: ...OIT to the computer using an RS 232 serial communications cable P N 7431 0049 purchased separately from Maple Systems The configuration cable should be connected to the proper COM port on your comput...

Page 14: ...the serial port farthest away from the power connector on the OIT3250 See Figure 10 below for Port 2 pin assignments NOTE Be particularly careful during wiring that Pins 8 and 9 on Port 2 are left ope...

Page 15: ...hen the OIT is configured Consult the OITware 200 manual for more information Connection to the printer varies depending upon the pinout of the printer See Figure 11 for the OIT Port 2 pin assignments...

Page 16: ...rnal Alarm Keypress Buzzers Outputs provided on Port 2 of the OIT3250 allow connections for external keypress and alarm buzzers The alarm buzzer output Pin 8 can be used to turn on an external buzzer...

Page 17: ...e is exposed to possible damage byelectrostatic discharge Refer toStatic Awareness onpage 4 2 Find the coin cell on the PCB It looks like a 1 2 inch 12 7 mm silver disk 3 Insert a small screwdriver in...

Page 18: ...e made on any non glossy stock between 0 004 inches 0 1 mm and 0 008 inches 0 2 mm thick by either of the following methods Photocopy the blank legends and hand illustrate Use the dimensions to create...

Page 19: ...81A REV 04 Middle Left 1 3 Right 2 Check Dimension 4 00 101 6 mm Tick marks indicate edge of viewable area F4 F8 F3 F2 F1 F7 F6 F5 F12 F11 F10 F9 Reads this way Function Keys and Logo Product ID Figur...

Page 20: ...on glossy stock which is 0 004 0 008 inches 0 1 0 2 mm thick Check printing accuracy with a printed check dimension 20 OIT3200 3250 1010 0081A REV 04 1 12 F8 Middle 0 50 Left 0 10 2 5 1 F4 3 F12 Right...

Page 21: ...refer to Figure 18 6 Carefully remove the factory installed legends 7 Slide in the new legends be gentle avoid wrinkling which makes it hard to push the legend in if the legend moves around too much p...

Page 22: ...t Liquid Crystal Display LCD 5 x 7 dot matrix with cursor Display Character Size 2 lines by 40 characters 0 2 inches 5 mm high Display Viewing Angle Approximately 120 degrees LEDs 24 for keypress and...

Page 23: ...F3 F7 F1 F5 Alarm Message 1 Next Message Down Page Page Up Help 7 Setup 4 Ack Last Print Screen 2 3 N 9 Toggle 0 8 R E T 6 5 E Delete Clear 152 4 6 00 9 25 234 9 49 5 1 95 9 7 0 38 2 45 62 1 3 33 4 8...

Page 24: ...K RED WIRE LIST Pin Shield 30 1 50 0 5 BLK SHIELD 3 RED 2 1 Power Connector 3 1 2 Signal Chassis Ground Signal Ground 12V to 30VDC OIT Push stripped wire into ROUND holes while holding clamps open wit...

Reviews: