PROCEDURE AFTER REPLACING THE MICROPROCESSOR, ETC
The procedure after replacing the u-COM (Microprocessor), flash ROM, etc. is as follows.
PWB Name
Ref. No. Description
After
replaced
Remark
MAIN
IC101
R5F56108VNFP
B
EXPLODED
f
P11
f
MODULE CY920-24C NA6005
D
MAIN
IC100
GD25Q32B
A
K1B
MAIN
IC109
MX25L25635FMI-10G
C
After replacing
A
: The software has been written. The software is not written at the time of replacement.
B
: The software has been written. The software may need to be rewritten by version updates. Check the version.
C
: The software has not been written. The software needs to be written after replacement. See “Firmware
UpdateProcedure” for information on writing the software.
D
: The software has been written. Be sure to rewrite with the latest software for your service region. See “Firmware Update
Procedure” for information on writing the software.