16
6. DPMS Force Update Mode
Updating the firmware by DPMS.
See
"2. Updating by DPMS" on page 29
.
Error code table
•
Preparation operation rewritten, Update error code checking. (Check ETHERNET unit)
Error Code
Details of Error code
Coping strategies
01
Login failed(DPMS Access Login Incorrect notification)
Reset and update again. Carry out the update in an environment
that has little network load.
02
Login failed(DPMS Access Server Busy information)
Carry out the update in an environment that has little network
load.
03
Login failed(DPMS Access link failure information)
Check the network connection. Carry out the update in an
environment that has little network load.
04
Firm Info response acquisition error recived
Check the network connection. Carry out the update in an
environment that has little network load.
05
Firm Info response acquisition TimeOut
Check the network connection. Carry out the update in an
environment that has little network load.
06
All Firm Info response acquisition error recived
Check the network connection. Carry out the update in an
environment that has little network load.
07
All Firm Info response acquisitionTimeOut
Check the network connection. Carry out the update in an
environment that has little network load.
08
Main Firm Info response acquisition error recived
Check the network connection. Carry out the update in an
environment that has little network load.
09
Main Firm Info response acquisition TimeOut
Check the network connection. Carry out the update in an
environment that has little network load.
0A
DownLoad failed ((NG)information recieved)
Check the network connection. Carry out the update in an
environment that has little network load.
0B
DownLoad failed((ServerBusy) information recieved)
Check the network connection. Carry out the update in an
environment that has little network load.
0C
DownLoad failed((connection failed)information
recived)
Check the network connection. Carry out the update in an
environment that has little network load.
•
Firm error codes at the main microprocessor rewritten. (Check the main microprocessor )
Error Code
Details of Error code
Coping strategies
10
Firm Info response acquisition TimeOut(Main rewrite
Firmware recived failure(TimeOut))
Turn off and on the power. Updating starts automatically.
11
Firm Info response acquisition recived error(Main
rewrite Firmware recived failure(Error)
Turn off and on the power. Updating starts automatically.
12
Firm Info response acquisition recived
error (Main rewirte Firmware recived data
incorrect(CheckSumError))
Turn off and on the power. Updating starts automatically.
13
Rewrite failure (BlockErase failued before Main
rewriting )
Turn off and on the power. Updating starts automatically.
14
Rewrite failure (BlockWrite failued before Main
rewriting)
Turn off and on the power. Updating starts automatically.
15
Rewrite failure (Verify incorrect after Main rewriting)
Turn off and on the power. Updating starts automatically.
20
Failed to acquire the IP Address after transitioning to
the Boot Loader Mode (AutoIP)
Carry out the update in an environment that has little network
load.
21
Failed to acquire the IP Address after transitioning to
the Boot Loader Mode (AutoIP)
Carry out the update in an environment that has little network
load.
22
Login failed (DPMS Access Login Incorrect notification),
after moved BootLoaderMode. (AutoIP)
Carry out the update in an environment that has little network
load.
23
Received "Server congestion" notification, after moved
BootLoaderMode. (AutoIP)
Carry out the update in an environment that has little network
load.
24
Received "connection failed", after moved
BootLoaderMode. (AutoIP)
Carry out the update in an environment that has little network
load.
36
Login failure(DPMSAccess Login incorrect infomation) Carry out the update in an environment that has little network
load.
37
Login failure(DPMSAccess Server busy infomation)
Carry out the update in an environment that has little network
load.
38
Login failure(DPMSAccess connection failed
infomation)
Check the network connection. Carry out the update in an
environment that has little network load.
39
Login failure(DPMSAccess access TimeOut)
Check the network connection. Carry out the update in an
environment that has little network load.
3A
DownLoad failure(Download error (NG)information
recieved)
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
3B
DownLoad failure(Download error (ServerBusy)
information recieved)
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
Summary of Contents for NA8005
Page 8: ...Personal notes 8 ...
Page 24: ...19 Personal notes ...
Page 38: ...38 Personal notes ...
Page 43: ...WIRING DIAGRAM 43 ...
Page 56: ...Personal notes Personal notes 56 ...
Page 62: ...62 PCM9211 DIGITAL IC42 PCM9211 Block Diagram ...
Page 63: ...63 PCM9211 Pin Discriptions ...
Page 66: ...66 CS2000 CP DIGITAL IC43 CS2000 CP Block Diagram ...
Page 69: ...69 MFI337S3959 DIGITAL IC25 ...
Page 70: ...70 2 DISPLAY S020 MXS4035A 3 ...