17
3C
DownLoad failure(Download error (connection failed)
information recived)
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
3D
Failed to acquire the IP Address after transitioning to
the Boot Loader Mode
(AutoIP)
"Turn off and on the power. Updating starts automatically.
Carry out the update in an environment that has little network
load."
3E
Failed to acquire the IP Address after transitioning to
the Boot Loader Mode (TimeOut)
"Turn off and on the power. Updating starts automatically.
Carry out the update in an environment that has little network
load."
•
CX870 system Firmware error codes when rewriting. (Check the ETHERNET unit)
Error Code
Details of Error code
Coping strategies
A0
Net not connected
Check the network connection. Carry out the update in an
environment that has little network load.
A1
Net Connection TimeOut can not get status
Check the network connection. Carry out the update in an
environment that has little network load.
A2
Login failed
Check the network connection. Carry out the update in an
environment that has little network load.
A3
Login failed
Check the network connection. Carry out the update in an
environment that has little network load.
A4
Login failed
Check the network connection. Carry out the update in an
environment that has little network load.
A6
Error receiving response FirmInfo acquisition
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
A7
FirmInfo Get Response TimeOut
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
A8
Net not connected
Check the network connection. Carry out the update in an
environment that has little network load.
A9
Net Connection TimeOut can not get status
Check the network connection. Carry out the update in an
environment that has little network load.
AA
After download request, Login Failed
Check the network connection. Carry out the update in an
environment that has little network load.
AB
After download request, Login Failed
Check the network connection. Carry out the update in an
environment that has little network load.
AC
After download request, Login Failed
Check the network connection.Carry out the update in an
environment that has little network load.
AE
Failure of DownLoad
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
AF
Failure of DownLoad
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
B0
Failure of DownLoad
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
B2
Update error
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
Failure to update, after the move again DM860 itselfe display retry processing
Summary of Contents for NA8005
Page 8: ...Personal notes 8 ...
Page 24: ...19 Personal notes ...
Page 38: ...38 Personal notes ...
Page 43: ...WIRING DIAGRAM 43 ...