DRAWN BY
UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN MILLIMETERS
TOLERANCES: LINEAR: +/-0.2mm
UC10 Installation guide
DESCRIPTION:
SCALE:1:8
FMc
02/11/11
536
585
395
min 50
min 50
min 130
3.5 buffer space
230
Electrical supply to machine
230V / 13A UK/ Europe
220V / 15A US.
Europe-
3/4” B.S.P water supply hose-Supplied
US-
No hose supplied.
2 wire Electrical
Connection 5V DC
If the vent is plumbed it
should be plumbed with
a tundish device.
Airspace
min 50
Note:
Dimensions specified are only guides.
Factors like ambient temperature, material
of counter will give rise to variances.
A vent system may need to be installed.
250
165
470
P/N:
1000821,
1000816,
1000811.
Outer
dimensions
denote outline
footprint of font.
Broken line
indicates cutout.
For exact drilling
template refer to
the font’s
instruction
manual.
Outlet water
connection.
Tube should be no
longer than 1m.
465
250
470